Evidence map›Paper›PMID 41066012›Full record

ArticleJournal of robotic surgery2025

Application and postoperative rehabilitation effects of HURWA, Cori, and Brainlab robots in TKA under the ERAS concept.

Mingyou Wang, Zhuodong Tang, Yuping Lan, Ruiqi Lan, Mingli Wang, Xunzhou Song, Hongping Wang

Abstract read
In one paragraph

Article in Journal of robotic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Trial
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mingyou Wang *Department of Orthopaedics, Panzhihua Central Hospital, No. 34 Yikang Street, Panzhihua, 617000, Sichuan, China.
Zhuodong Tang *Department of Orthopaedics, Panzhihua Central Hospital, No. 34 Yikang Street, Panzhihua, 617000, Sichuan, China.
Yuping LanDepartment of Orthopaedics, Panzhihua Central Hospital, No. 34 Yikang Street, Panzhihua, 617000, Sichuan, China.
Ruiqi LanDepartment of Orthopaedics, Panzhihua Central Hospital, No. 34 Yikang Street, Panzhihua, 617000, Sichuan, China.
Mingli WangDepartment of Orthopaedics, Panzhihua Central Hospital, No. 34 Yikang Street, Panzhihua, 617000, Sichuan, China.
Xunzhou SongDepartment of Orthopaedics, Panzhihua Central Hospital, No. 34 Yikang Street, Panzhihua, 617000, Sichuan, China.
Hongping WangDepartment of Orthopaedics, Panzhihua Central Hospital, No. 34 Yikang Street, Panzhihua, 617000, Sichuan, China. wmy1241317@163.com.

Funding

Chengdu High-tech Medical Association "2023 annual Flurbiprofen gel paste treatment of osteoarthritis special research fund" project 2024013Research Project of Sichuan Society of Gerontology 24SCLN092Sichuan Medical Association Orthopedics (Shang Antong) special research project 2023SAT14Sichuan Provincial Primary Health Development Research Center in 2024, North Sichuan Medical College SWFZ24-Q-86
6 · The paper itself

Abstract

As science and technology continue to progress, the variety and number of robots used in assisted total knee arthroplasty (TKA) have steadily increased, allowing more surgeons and patients to benefit from enhanced medical precision and improved knee joint function, ultimately leading to a better quality of life. This retrospective study compared the outcomes of 164 patients undergoing total knee arthroplasty (TKA), either conventionally or assisted by one of three robotic systems (Brainlab, HURWA, or Stryker Cori), all within an Enhanced Recovery After Surgery (ERAS) protocol. Whilst robotic groups had longer incisions and the Brainlab system required more time, the domestic HURWA robot demonstrated superior performance in achieving optimal FFC and LFC angles. By postoperative day 3, the Brainlab group reported higher pain scores, but this difference resolved by 90 days. Crucially, there were no significant differences in final knee function (KSS, ROM), inflammatory markers, blood loss, complication rates, or patient satisfaction (all > 95%) between any groups. The findings indicate that despite early variations, all three robotic systems facilitate effective recovery and satisfactory clinical outcomes comparable to conventional TKA under ERAS, without increasing perioperative risks.

Indexed as

Arthroplasty, Replacement, KneeEnhanced Recovery After SurgeryRobotic Surgical ProceduresAgedFemaleHumansKnee JointMaleMiddle AgedPatient SatisfactionPostoperative ComplicationsRecovery of FunctionRetrospective StudiesTreatment OutcomeEnhanced Recovery after SurgeryKnee osteoarthritisSurgical robotsTotal knee arthroplasty

Identifiers

PMID41066012
PMCPMC12511198

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.