Motion correction in CBCT imaging using gate-less model-based reconstruction of non-rigid motion and images.

Ethan Waterink, Rodrigo José Santo, Cornelis A T van den Berg, Alessandro Sbrizzi, Casper Beijst

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ethan WaterinkDepartment of Radiotherapy, Utrecht University and University Medical Center Utrecht, Utrecht, The Netherlands.
Rodrigo José SantoDepartment of Radiotherapy, Utrecht University and University Medical Center Utrecht, Utrecht, The Netherlands.
Cornelis A T van den BergDepartment of Radiotherapy, Utrecht University and University Medical Center Utrecht, Utrecht, The Netherlands.
Alessandro SbrizziDepartment of Radiotherapy, Utrecht University and University Medical Center Utrecht, Utrecht, The Netherlands.
Casper BeijstDepartment of Radiotherapy, Utrecht University and University Medical Center Utrecht, Utrecht, The Netherlands.

Funding

Dutch Cancer Society 14848Netherlands Organisation for Scientific Research 19003
6 · The paper itself

Abstract

backgroundCone beam computed tomography (CBCT) plays a crucial role in verifying patient positioning during radiotherapy. However, CBCT images are often blurred by motion originating from breathing, bowel motion, and/or repositioning. Conventional methods often employ gating techniques to mitigate motion artifacts by assuming periodicity, which is restricted to respiratory motion. However, this does not resolve a-periodic motion such as irregular breathing. PURPOSE: The purpose of this study is to estimate and correct for both periodic motion and irregular motion. We present a novel method for gate-less reconstruction of motion and images (CBCT-MOTUS), thereby estimating and correcting for all non-rigid 3D motion at high temporal frequency (per-projection temporal resolution of 182 ms).

methodsStarting from a motion-corrupted image, we perform the reconstruction process by alternating between a motion estimation step and an image correction step. Motion estimation is model-based, that is, it is performed directly in projection space by comparing acquired projections to simulated projections that take motion-fields into account. The optimization process benefits from assumptions, including (i) compressing the motion-fields using B-spline parameterization to reduce the number of parameters to estimate, (ii) exploiting spatio-temporal correlation of motion using a low-rank motion model, and (iii) enforcing smoothness using spatial regularization to include a priori knowledge on motion-fields. High temporal resolution (182 ms for this scanner) is achieved as motion-fields are estimated for each acquired gantry angle. The method is validated in silico, on phantoms and on clinical in vivo acquisitions.

resultsThe framework can estimate and correct irregular and periodic motion with high temporal resolution (per-projection temporal resolution of 182 ms). The motion-corrected images show improved image features for all experiments with reduction of motion artifacts, such as deblurring on organ interfaces.

conclusionsWe have developed and validated a gate-less reconstruction method (CBCT-MOTUS) for model-based motion estimation and correction in CBCT imaging for any kind of motion. High temporal resolution (per-projection temporal resolution of 182 ms) is achieved by exploiting the smoothness and compressibility of motion using a low-rank B-spline motion model, enabling the correction for non-rigid irregular and periodic motion. These proof-of-principle results warrant further clinical validation.

Indexed as

Cone-Beam Computed TomographyImage Processing, Computer-AssistedArtifactsHumansMovementPhantoms, ImagingRespirationCBCT motion correctiongate‐less motion reconstructionmodel‐based non‐rigid motion

Identifiers

PMID41065309
PMCPMC12509791

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.