Simultaneous signal optimization of refraction and attenuation in x-ray grating interferometry: A case study for breast imaging.

Alexandre Pereira, Michał Rawlik, Simon Spindler, Stefanie Kaser, Dominik Etter, Gianluca Iori, Martin Stauber, Lucia Romano, Marco Stampanoni

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Alexandre PereiraInstitute for Biomedical Engineering, ETH Zürich and University of Zürich, Zürich, Switzerland.
Michał RawlikInstitute for Biomedical Engineering, ETH Zürich and University of Zürich, Zürich, Switzerland.
Simon SpindlerInstitute for Biomedical Engineering, ETH Zürich and University of Zürich, Zürich, Switzerland.
Stefanie KaserInstitute for Biomedical Engineering, ETH Zürich and University of Zürich, Zürich, Switzerland.
Dominik EtterInstitute for Biomedical Engineering, ETH Zürich and University of Zürich, Zürich, Switzerland.
Gianluca IoriInstitute for Biomedical Engineering, ETH Zürich and University of Zürich, Zürich, Switzerland.
Martin StauberGratXray, Villigen, Switzerland.
Lucia RomanoInstitute for Biomedical Engineering, ETH Zürich and University of Zürich, Zürich, Switzerland.
Marco StampanoniInstitute for Biomedical Engineering, ETH Zürich and University of Zürich, Zürich, Switzerland.

Funding

PHRT-Booster 2024-985 NAVIGATORPHRT-Pioneer 2021-612 CLARINETPHRT-TT 2022-572 INTIMACYPromedica Stiftung Chur 1527Promedica Stiftung Chur 1788/MSNF Grant 10001625SNF Sinergia Grant 183568SwissLOS Lottery Fund of Kanton Aargau
6 · The paper itself

Abstract

backgroundX-ray grating interferometry has emerged as a promising imaging technique for breast computed tomography (BCT), offering complementary contrast from refraction beyond conventional absorption imaging. Although it provides higher resolution, the required dose levels remain above those typically used for breast cancer diagnostic imaging. PURPOSE: This study aims to design an optimized grating interferometry-based BCT system using a novel optimization metric that simultaneously maximizes signal strength from refraction and attenuation while considering grating fabrication and system constraints.

methodsA systematic grid search was conducted to identify system configurations that optimize contrast-to-noise ratio while accounting for dose efficiency in both attenuation and refraction. The optimized system was benchmarked against a commercial absorption-based BCT system and a previously published grating interferometry design. Simulations were performed using in silico breast phantoms of varying diameters, incorporating realistic imaging conditions and noise modeling across dose levels from 1 to 100 mGy. Additionally, a signal fusion technique was applied to combine the two contrast channels.

resultsQuantitative analysis demonstrates that refraction provides superior contrast for small malignancies, while absorption remains beneficial for larger lesions. Fusing both contrast channels enhances the contrast-to-noise ratio and improves resolution in in silico reconstructed images, outperforming conventional absorption-based BCT at dose levels relevant for breast cancer diagnostic imaging.

conclusionsThe findings suggest that an optimized grating interferometry-based BCT system can improve image quality by effectively combining absorption and refraction signals. This work underscores the need to balance imaging performance with practical implementation constraints, offering a framework that may extend to other imaging applications beyond breast cancer detection.

Indexed as

BreastInterferometryMammographyTomography, X-Ray ComputedBreast NeoplasmsFemaleHumansImage Processing, Computer-AssistedPhantoms, ImagingSignal-To-Noise Ratiobreast imaginggrating interferometrysystem design

Identifiers

PMID41065307
PMCPMC12509792

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.