Evidence map›Paper›PMID 41065293›Full record

ArticleJournal of clinical laboratory analysis2025

Comparative Evaluation of Centrifugation Speed and Its Impact on Diagnostic Accuracy.

Mohammed A Jeraiby, Jobran M Moshi, Sajad A Dar, Mahmoud M Habibullah, Mjery Yahia, Saif Elden B Abdalla, Raheem M Balkhtab, Renad A Saigh, Nahlah S Burayk

Abstract readComparative Study
In one paragraph

Article in Journal of clinical laboratory analysis, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mohammed A JeraibyDepartment of Basic Medical Science, College of Medicine, Jazan University, Jazan, Saudi Arabia.
Jobran M MoshiDepartment of Medical Laboratory Technology, College of Nursing and Health Science, Jazan University, Jazan, Saudi Arabia.
Sajad A DarDepartment of Nursing, College of Nursing and Health Science, Jazan University, Jazan, Saudi Arabia.ORCID https://orcid.org/0000-0003-2499-8701
Mahmoud M HabibullahDepartment of Medical Laboratory Technology, College of Nursing and Health Science, Jazan University, Jazan, Saudi Arabia.ORCID https://orcid.org/0000-0002-4155-3379
Mjery YahiaDepartment of Medical Laboratory Technology, College of Nursing and Health Science, Jazan University, Jazan, Saudi Arabia.
Saif Elden B AbdallaDepartment of Medical Laboratory Technology, College of Nursing and Health Science, Jazan University, Jazan, Saudi Arabia.
Raheem M BalkhtabDepartment of Laboratory, Jazan University Hospital, Jazan, Saudi Arabia.
Renad A SaighDepartment of Laboratory, Jazan University Hospital, Jazan, Saudi Arabia.
Nahlah S BuraykDepartment of Laboratory, Jazan University Hospital, Jazan, Saudi Arabia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionTimely laboratory results are essential for effective clinical decision-making, with turnaround time (TAT) serving as a key performance indicator. Pre-analytical steps like centrifugation significantly impact TAT. This study investigates whether a shorter, high-speed centrifugation can reduce TAT while maintaining the analytical accuracy required for routine diagnostic testing. METHODOLOGY: This comparative experimental study analyzed blood samples from patients using plasma and serum tubes. Two centrifugation methods (A: (routine) 10 min at 3200 g; B: (faster) 5 min at 4000 g) were compared across chemistry, immunochemistry, coagulation, and interference indices.

resultsMost analytes showed no significant difference between the two methods, indicating strong analytical agreement. However, significant differences were observed in sodium (p = 0.003), CKMB (p = 0.044), ALP (p = 0.001), ALT (p = 0.011), FRT4 (p < 0.001), PT (p = 0.008), and INR (p = 0.003). Despite these differences, all values remained within clinically acceptable ranges. Hemolysis rates decreased notably under the high-speed method, dropping from 10.4% to 5.1%. Bias analysis across tube types revealed greater variability for CKMB and ALT under the high-speed method (bias = 2.76 and -2.92; CVs = 68.8% and 84.16%, respectively).

conclusionHigh-speed centrifugation significantly reduces processing time without compromising clinical reliability. Despite minor analyte differences, all values ramined within acceptable clinical ranges. Furthermore, the observed reduction in hemolysis rates strengthens the case for adopting the high-speed method as a reliable, efficient, and clinically safe alternative for routine laboratory workflows.

Indexed as

Blood Specimen CollectionCentrifugationHemolysisHumansReproducibility of Resultscentrifugation speedclinical laboratory testingdiagnostic accuracyhemolysis rate

Identifiers

PMID41065293
PMCPMC12699201

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.