ArticleJournal of orthopaedic surgery and research2025
Biomechanical analysis of biodegradable magnesium, zinc, and polylactide pins for fixation of radial head fractures.
Article in Journal of orthopaedic surgery and research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- A biomechanical comparison of closed-reduction osteosynthesis techniques for fractures of the ulnar styloid.Journal of orthopaedic surgery and research · 2026Article
- Outcomes and complications of metallic vs. bioabsorbable screw fixation for displaced medial epicondylar fractures in pediatric and adolescent patients.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026Article
- Biomechanical evaluation of biodegradable zinc and polylactide pins for radial head fracture fixation: a human cadaver study.Journal of orthopaedic surgery and research · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundBiodegradable implants have raised constant interest for fixation of displaced radial head fractures due to avoiding implant removal and minimizing cartilage damage. Polylactide pins (PP) are frequently used in clinical practice, but inferior mechanical properties showed higher rates of secondary dislocation compared to metal implants. Magnesium pins (MP) provide superior stability but exhibit inconsistent resorption and relevant hydrogen gas formation. Recently, zinc pins (ZP) have emerged as a promising alternative, offering comparable mechanical strength with favourable biocompatibility. Since these implants have not been tested for specific fracture fixation, this study aims to evaluate their applicability in a validated Mason type II radial head fracture model.
methodsStandardized Mason type II fractures were conducted in biomechanically validated composite radii, and fixed by using either two 2.0 mm MPs, ZPs, or PPs. Biomechanical testing included 10 cycles of transverse loading, 1,000 cycles of axial loading (15-50 N at 0.1 Hz), and load-to-failure testing (2 N/sec). Stability was assessed by stiffness (kN/mm) under axial and transverse loading, fracture displacement (mm) after 1,000 cycles, and failure load (N) at dislocation ≥ 2 mm.
resultsMPs demonstrated the highest primary stability, followed by ZPs and PPs under both transverse (PP: 0.36 ± 0.08 kN/mm vs. MP: 1.30 ± 0.31 kN/mm, p < .001; vs. ZP: 0.87 ± 0.33 kN/mm, p = .012) and axial loading (PP: 0.43 ± 0.10 kN/mm vs. MP: 1.25 ± 0.31 kN/mm, p < .001; vs. ZP: 0.77 ± 0.18 kN/mm, p = .035). Fracture displacement after 1,000 cycles was lower with MPs and ZPs than PPs (PP: 0.038 ± 0.009 mm vs. MP: 0.013 ± 0.003 mm, p < .001; vs. ZP: 0.022 ± 0.007 mm, p = .003). MPs (282 ± 26 N) showed the highest load-to-failure at 2 mm dislocation, followed by ZPs (261 ± 38 N) and PPs (215 ± 53 N) (PP vs. MP: p = .032; PP vs. ZP: p = .164; MP vs. ZP p = .650).
conclusionIn this biomechanical model of Mason type II radial head fractures, biodegradable magnesium and zinc pins demonstrated superior primary stability and load-bearing capacity compared to polylactide implants. MP showed the highest stiffness and lowest fracture displacement, while ZP achieved comparable performance in fracture stabilization. These findings suggest that zinc-based implants could offer a clinically valuable alternative for radial head fracture fixation, potentially reducing complications seen with the other implants. Further in-vivo, cadaveric, and clinical studies are necessary to confirm long-term outcomes and biological integration. LEVEL OF EVIDENCE: Basic Science Study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.