Evidence map›Paper›PMID 41062631›Full record

ArticleScientific reports2025

Power system security and protection considering the integration of new energy power plants.

Shengda Wang, Danni Liu, Weijia Su, Xiaojuan Zhang, Shichun Hui

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Shengda WangJiLin Information & Telecommunication Company, State Grid Jilin Electric Power Corporation Ltd., Changchun, 130000, China.
Danni LiuJiLin Information & Telecommunication Company, State Grid Jilin Electric Power Corporation Ltd., Changchun, 130000, China. liudanni1212@163.com.
Weijia SuJiLin Information & Telecommunication Company, State Grid Jilin Electric Power Corporation Ltd., Changchun, 130000, China.
Xiaojuan ZhangInformation and Communication Department China Electrical Power Research Institute Department, Beijing, 100192, China.
Shichun HuiJiLin Information & Telecommunication Company, State Grid Jilin Electric Power Corporation Ltd., Changchun, 130000, China.

Funding

Unveiling Projects(Research on Access Security Immunity Technology of New Energy Power Plant System under New Power System)of State Grid Jilin Electric Power Corporation Ltd. 2021JBGS-08
6 · The paper itself

Abstract

Power quality disturbances (PQDs) pose significant challenges in modern energy power plants-based systems (MEPPBS), especially with the increasing integration of renewable energy sources (RESs) such as wind and solar photovoltaic (PV) systems. The intermittent nature of these sources introduces voltage fluctuations, harmonics, and transient disturbances, affecting grid stability and reliability. This paper presents a novel dual algorithm-based protection approach for detecting, classifying, and mitigating PQDs in grid-connected MEPPBS. The proposed method utilized an advanced adaptive median filter (AMF) as a signal processing-state observer and a support vector machine (SVM)-based scheme to accurately identify disturbances, including voltage sags, swells, harmonics, interruptions, and transients. The proposed dual-algorithm approach, combining AMF and SVM, offers a novel solution that enhances PQD detection accuracy and speed compared to existing methods. Furthermore, the proposed scheme tests five individual PQDs and ten combined disturbances-based datasets, including voltage sags, swells, harmonics, interruptions, and transients were used to train the proposed SVM classifier. Then, SVM-based residuals were calculated by SVM algorithms from estimated AMF data, SVMBR index reveals the detection of PQDs quickly. Simulations were performed in MATLAB® R2022b (Version 9.13) to evaluate the effectiveness of the suggested approach under various operating conditions. The results demonstrate high detection accuracy of 97%, fast response times of less than 15 milliseconds, & robustness in discriminating different PQDs when trained by just 50% of the dataset under a signal-to-noise ratio (SNR) of 20dB. The proposed method achieves 96% precision, 94% recall, and a 0.04 false positive rate, demonstrating high accuracy and reliability in PQDs detection. The findings highlight the potential of the presented method to enhance power system resilience and ensure reliable operation in renewable energy-integrated grids.

Indexed as

New energy power plantsPower quality disturbancesPower system protectionPower system securitySmart gridsState observersSupport vector machine

Identifiers

PMID41062631
PMCPMC12508190

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.