Challenging the Database: Day-of-Analysis Calibration and UF Modeling for Reliable RRF Use in Medical Device Chemical Characterization.
Article in Analytical chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Accurate quantitation during chemical characterization─also referred to as extractables and leachables (E&L)─within a toxicological risk assessment for medical device biocompatibility hinges on the appropriate application of relative response factors (RRFs). This study investigates the variability of RRFs across a chemically diverse set of compounds and evaluates the implications of quantitation model selection on analytical outcomes. Using gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS), we demonstrate that RRFs are highly context-dependent and influenced by factors such as ionization mode, compound class, concentration, and instrument conditions. We propose an approach to RRF determination, emphasizing day-of-analysis calibration and uncertainty factor modeling to improve reproducibility. Our findings support a statistically grounded application of analytical evaluation thresholds, enhancing the reliability of semiquantitative assessments in medical device biocompatibility.