Evidence map›Paper›PMID 41058609›Full record

ArticleJPhys photonics2025

Isolating subsurface fluorescence in macroscopic lifetime imaging via high-spatial-frequency structured illumination.

Nanxue Yuan, Saif Ragab, Navid Nizam, Vikas Pandey, Amit Verma, Tynan Young, John Williams, Margarida Barroso, Xavier Intes

Abstract read
In one paragraph

Article in JPhys photonics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

9 authors.

Nanxue YuanCenter for modeling, simulation and Imaging in Medicine, Rensselaer Polytechnic Institute, Troy, NY 12180, United States of America.ORCID https://orcid.org/0009-0004-8112-0959
Saif RagabCenter for modeling, simulation and Imaging in Medicine, Rensselaer Polytechnic Institute, Troy, NY 12180, United States of America.
Navid NizamDepartment of Biomedical Engineering, West Chester University, West Chester, PA 19380, United States of America.ORCID https://orcid.org/0000-0002-8266-5254
Vikas PandeyCenter for modeling, simulation and Imaging in Medicine, Rensselaer Polytechnic Institute, Troy, NY 12180, United States of America.ORCID https://orcid.org/0000-0001-5477-1095
Amit VermaDepartment of Molecular and Cellular Physiology, Albany Medical College, Albany, NY 12208, United States of America.
Tynan YoungCity of Hope, Beckman Research Institute, Department of Molecular Medicine, Duarte, CA 91016, United States of America.
John WilliamsCity of Hope, Beckman Research Institute, Department of Molecular Medicine, Duarte, CA 91016, United States of America.
Margarida BarrosoDepartment of Molecular and Cellular Physiology, Albany Medical College, Albany, NY 12208, United States of America.ORCID https://orcid.org/0000-0002-0407-3181
Xavier IntesCenter for modeling, simulation and Imaging in Medicine, Rensselaer Polytechnic Institute, Troy, NY 12180, United States of America.

Funding

In vivo Macroscopic Fluorescence Lifetime Molecular Optical ImagingR01CA250636 · NCI · RENSSELAER POLYTECHNIC INSTITUTE · PI BARROSO, MARGARIDA, INTES, XAVIER · 2020 to 2023
$2.9M
Photon-counting X-ray and Optical Tomography for Preclinical Cancer ResearchR01CA237267 · NCI · RENSSELAER POLYTECHNIC INSTITUTE · PI BARROSO, MARGARIDA, INTES, XAVIER · 2019 to 2023
$2.9M
AI enhanced lifetime-based mesoscopic in vivo imaging of tissue molecular heterogeneityR01CA271371 · NCI · RENSSELAER POLYTECHNIC INSTITUTE · PI Margarida Barroso, Xavier Intes · 2023 to 2026
$2.7M
NCI NIH HHS R01 CA237267NCI NIH HHS R01 CA250636NCI NIH HHS R01 CA271371
6 · The paper itself

Abstract

Macroscopic fluorescence lifetime imaging (MFLI) has emerged as a robust, non-invasive imaging technique offering quantitative insights into physiological and molecular processes within live tissues, independent of fluorophore concentration, excitation intensity, or signal attenuation. However, a key limitation is the inability to accurately determine the depth at which fluorescence signals originate, potentially compromising biological interpretation due to ambiguous localization. In this study, we introduce high spatial frequency-fluorescence lifetime imaging (HSF-FLI), an innovative optical correction methodology designed to effectively eliminate surface signal bias, such as those arising from skin in preclinical imaging, without requiring chemical clearing agents. We develop a modulation transfer function linking spatial frequency with signal penetration depth through comprehensive Monte Carlo eXtreme simulations. Utilizing structured, three-phase sinusoidal illumination, fluorescence signals were accurately decomposed into distinct surface and subsurface components. Experimental validation was performed using agar-based capillary phantoms and a time-gated intensified charged coupled device coupled with a digital micromirror device imaging system. Further demonstrating its practical utility, we successfully applied HSF-FLI to preclinical drug delivery assessments employing Förster resonance energy transfer MFLI. The method was rigorously validated