Evidence map›Paper›PMID 41057492›Full record

ArticleScientific reports2025

Quantification of head leakage radiation in CyberKnife robotic radiosurgery systems using a multimodal approach.

Sandeep Singh, Manindra Bhushan, Pawan Kumar Singh, Debasish Sahoo, Supratik Sen, Dipesh, Abhay Kumar Singh, Mahipal, Munish Gairola

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Sandeep SinghDepartment of Radiation Oncology, Division of Medical Physics, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India. sandeep.singh82a@gmail.com.
Manindra BhushanDepartment of Radiation Oncology, Division of Medical Physics, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India.
Pawan Kumar SinghDepartment of Radiation Oncology, VMMC & Safdarjung Hospital, New Delhi, India.
Debasish SahooDepartment of Radiation Oncology, Homi Bhabha Cancer Hospital and research Center, Visakhapatnam, India.
Supratik SenDepartment of Radiation Oncology, Division of Medical Physics, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India.
DipeshDepartment of Radiation Oncology, Division of Medical Physics, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India.
Abhay Kumar SinghDepartment of Radiation Oncology, Division of Medical Physics, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India.
MahipalDepartment of Radiation Oncology, Division of Medical Physics, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India.
Munish GairolaDepartment of Radiation Oncology, Division of Medical Physics, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aims to measure the head leakage radiation of a CyberKnife system (Model-S7 (without MLC)) in-patient and out-of-patient planes using optically stimulated luminescence dosimeters (OSLDs), vented ionization chambers, and a pressurized ionization chamber-based survey meter, and to compare the measured leakage levels with the limits specified by the International Electrotechnical Commission (IEC) standards. In this study, a CyberKnife LINAC equipped with a 6 MV flattening filter-free (FFF) beam and a maximum circular field size of 6 cm in diameter was utilized. Leakage radiation was assessed for both IRIS and FIXED collimators in their fully closed positions. Three independent measurement techniques were employed to quantify leakage: optically stimulated luminescence dosimeters (OSLDs), vented ionization chambers (ICs), and a pressurized ionization chamber-based survey meter (SM). Leakage measurement points were taken as per the IEC 60601-2-1 report both for in-patient plane and out-of-patient plane. The total number of monitor units (MU) delivered were 500 MU's. The measured average in-patient plane leakage was 0.015% using IC, 0.100% using OSLD and 0.010% using SM, that is well within the tolerance limit of 0.1% according to IEC guidelines. The average leakage for out of patient plane was 0.037%, which is well within the limit of 0.5% as per IEC guidelines. The study measured head leakage radiation of the CyberKnife System using OSLD, ionization chambers, and a survey meter. Leakage levels for both in-patient and out-of-patient planes were significantly below the IEC 60601-2-1 standard limits. This confirms the system's compliance with safety guidelines, ensuring minimal radiation exposure.

Indexed as

HeadRadiosurgeryRobotic Surgical ProceduresHumansRadiometryIn-patient planeLeakageOSLDOut of patient planeSurvey meter

Identifiers

PMID41057492
PMCPMC12504714

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.