Evidence map›Paper›PMID 41057436›Full record

ArticleScientific reports2025

Rapid reagent free COVID19 detection using MEMS based FTIR spectroscopy and machine learning in NIR and MIR regions.

Ahmed Abdelkhalik, Mazen Erfan, Bassem Mortada, Mohamed Gaber, Shereen Saeed, Ghada Ismail, Ahmed ElShafei, MennaAllah S Mohamed, Bassam Saadany, Yasser M Sabry and 1 more

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Ahmed AbdelkhalikSi-Ware Systems, 3 Khaled Ibn El-Waleed Street, Heliopolis, Cairo, Egypt.
Mazen ErfanSi-Ware Systems, 3 Khaled Ibn El-Waleed Street, Heliopolis, Cairo, Egypt. mazen.erfan@eng.asu.edu.eg.
Bassem MortadaSi-Ware Systems, 3 Khaled Ibn El-Waleed Street, Heliopolis, Cairo, Egypt.
Mohamed GaberSi-Ware Systems, 3 Khaled Ibn El-Waleed Street, Heliopolis, Cairo, Egypt.
Shereen SaeedReference Laboratory of the Egyptian University Hospitals, Cairo, Egypt.
Ghada IsmailReference Laboratory of the Egyptian University Hospitals, Cairo, Egypt.
Ahmed ElShafeiModern University for Information and Technology, Cairo, Egypt.
MennaAllah S MohamedFaculty of Medicine, Clinical Pathology department, Ain shams University, Cairo, Egypt.
Bassam SaadanySi-Ware Systems, 3 Khaled Ibn El-Waleed Street, Heliopolis, Cairo, Egypt.
Yasser M SabrySi-Ware Systems, 3 Khaled Ibn El-Waleed Street, Heliopolis, Cairo, Egypt. yasser.sabry@eng.asu.edu.eg.
Diaa KhalilSi-Ware Systems, 3 Khaled Ibn El-Waleed Street, Heliopolis, Cairo, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study presents rapid, reagent-free detection of COVID-19 using miniaturized MEMS-based Fourier-transform infrared (FTIR) spectrometers integrated with machine learning models. Two portable spectrometers analyze 363 nasopharyngeal swab samples stored in viral transport medium (VTM). The first spectrometer covers the near-infrared (NIR) region (1.3-2.6 μm) and second spectrometer extends from the near infrared to the mid infrared (MIR) region (1.75-4.0 μm). The NIR system uses a transmission configuration, while the one extended to the MIR performs attenuated total reflectance (ATR) measurements on both wet and dried samples. Spectral data undergo preprocessing and analysis using interval partial least squares discriminant analysis (iPLS-DA), with model training and evaluation conducted through Monte Carlo cross-validation. The MIR wet sample model achieves a diagnostic performance with 79% accuracy, a 98% sensitivity, and an area under the curve (AUC) of 0.8. The MIR dry sample model achieves an 80% accuracy and an AUC of 0.79, while the NIR model reaches 66% accuracy and an AUC of 0.64. Spectral features appear in the Amide A and B regions in the MIR range, and in the C-H overtone bands in the NIR range. The full measurement process, including sample handling, completes in under six minutes, supporting its suitability for real-time, point-of-care (POC) testing.

Indexed as

COVID-19COVID-19 TestingMachine LearningSARS-CoV-2HumansSpectroscopy, Fourier Transform InfraredSpectroscopy, Near-InfraredATRCOVID-19Infectious diseaseMEMS FTIR spectrometerMIR spectroscopyNIR spectroscopyPCR

Identifiers

PMID41057436
PMCPMC12504735

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked