ArticleScientific reports2025
Tracking control of air flow based on a fractional-order model of the lung impedance.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
A fractional order output feedback controller for a lung ventilator is designed. This is based on a state-of-the-art electrical analogue model of the human respiratory system in the form of a network of resistors and fractional capacitors. The electrical input impedance of the adopted analogue can be suitably tuned to fit experimental ventilation impedance data. Furthermore, it can explicitly account for the different physiological fractal type characteristics associated with lung formation such as branching morphogenesis associated to the treelike tubular network and alveolar differentiation associated with the generation of specialized epithelial cells for gas exchange. A description of this electrical analogue in pseudo-state space is then proposed. The aim is to finally provide a control methodology within the scope of output feedback control, when the measured output which is the airflow through the trachea is directed to follow a specified reference. The control provides adequate air pressure input to generate this nominal airflow. The proposed control design includes a pseudo-state observer and a double leaky integrator. The gains involved are designed using constraints imposed through linear matrix inequalities (LMIs), which enforce a regional allocation of eigenvalues. The robustness of the control loop is analysed through an uncertainty matrix analysis linked directly to the model. It is observed that the proposed design can tolerate a relatively wide variation in physiological parameters ([Formula: see text]). The proposed formulation advances current control design approaches for mechanical ventilators and provides a generic methodology for the control of complex system with emergent responses as encountered in bioengineering.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.