Evidence map›Paper›PMID 41055831›Full record

ArticleInternational journal of computer assisted radiology and surgery2026

Neural illumination calibration for surgical workflow-optimized spectral imaging.

Alexander Baumann, Leonardo Ayala, Alexander Studier-Fischer, Jan Sellner, Berkin Özdemir, Karl-Friedrich Kowalewski, Slobodan Ilic, Silvia Seidlitz, Lena Maier-Hein

Abstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Alexander BaumannSiemens AG, Munich, Germany. baumann.alexander@siemens.com.
Leonardo AyalaDivision of Intelligent Medical Systems, German Cancer Research Center (DKFZ) Heidelberg, Heidelberg, Germany.
Alexander Studier-FischerDepartment of General, Visceral, and Transplantation Surgery, Heidelberg University Hospital, Heidelberg, Germany.
Jan SellnerDivision of Intelligent Medical Systems, German Cancer Research Center (DKFZ) Heidelberg, Heidelberg, Germany.
Berkin ÖzdemirDepartment of General, Visceral, and Transplantation Surgery, Heidelberg University Hospital, Heidelberg, Germany.
Karl-Friedrich KowalewskiDepartment of Urology and Urosurgery, University Medical Center Mannheim, Mannheim, Germany.
Slobodan IlicSiemens AG, Munich, Germany.
Silvia Seidlitz *Division of Intelligent Medical Systems, German Cancer Research Center (DKFZ) Heidelberg, Heidelberg, Germany.
Lena Maier-Hein *Division of Intelligent Medical Systems, German Cancer Research Center (DKFZ) Heidelberg, Heidelberg, Germany.

Funding

HORIZON EUROPE European Research Council 101002198
6 · The paper itself

Abstract

purposeHyperspectral imaging (HSI) is emerging as a promising novel imaging modality with various potential surgical applications. Currently available cameras, however, suffer from poor integration into the clinical workflow because they require the lights to be switched off or the camera to be manually recalibrated as soon as lighting conditions change.

methodsWe propose a novel learning-based approach to recalibration of hyperspectral cameras during surgery that predicts the corresponding white reference image from an uncalibrated hyperspectral input, enabling spatially resolved, automatic, and sterile calibration under varying illumination conditions. Our key novelty lies in (i) the disentanglement of the space of possible illuminations from the space of possible tissue configurations and (ii) combining real-world white reference measurements with physics-inspired simulated illuminations to create a diverse and representative training set.

resultsBased on a total of 1,890 HSI cubes from a phantom, porcine subjects, rats, and humans, we derive the following key insights: Firstly, dynamically changing lighting conditions in the operating room dramatically reduce the performance of methods for physiological parameter estimation and surgical scene segmentation. Secondly, our method is not only sufficiently accurate to replace the tedious process of white reference-based recalibration, but also outperforms previously proposed methods by a large margin. Finally, our approach generalizes across species, lighting conditions, and image processing tasks.

conclusionOur method enables seamless integration of hyperspectral imaging into surgical workflows by providing rapid and automated illumination calibration. Its robust generalization across diverse conditions significantly enhances the reliability and practicality of spectral imaging in clinical settings, paving the way for broader adoption of HSI in surgery.

Indexed as

Hyperspectral ImagingLightingSurgery, Computer-AssistedAnimalsCalibrationHumansPhantoms, ImagingRatsSwineWorkflowDeep LearningHyperspectral ImagingIllumination CalibrationIntra-Operative Imaging

Identifiers

PMID41055831
PMCPMC13194271

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.