Evidence map›Paper›PMID 41054442›Full record

ArticleEClinicalMedicine2025

Laboratory evaluation of 185 commercial assays for detecting SARS-CoV-2: the UK response for mass testing.

Abbie Bown, Tim Peto, Angela Sweed, Matthew Catton, Joshua Nelthorpe-Cowne, Tracy Benford, LFD Laboratory Team, LFD Laboratory Support Team, Tom Collinge, Donna Robinson and 10 more

Abstract read
In one paragraph

Article in EClinicalMedicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

20 authors.

Abbie BownUK Health Security Agency, Porton, UK.
Tim PetoOxford University Hospitals NHS Foundation Trust, Oxford, UK.
Angela SweedUK Health Security Agency, Porton, UK.
Matthew CattonUK Health Security Agency, Porton, UK.
Joshua Nelthorpe-CowneUK Health Security Agency, Porton, UK.
Tracy BenfordUK Health Security Agency, Porton, UK.
LFD Laboratory Team
LFD Laboratory Support Team
Tom CollingeTesting Operations (COVID 19), UK Health Security Agency, UK.
Donna RobinsonTesting Operations (COVID 19), UK Health Security Agency, UK.
Louise OliverTesting Operations (COVID 19), UK Health Security Agency, UK.
Susan HopkinsClinical and Public Health Group, UK Health Security Agency, UK.
Derrick CrookNuffield Department of Medicine, University of Oxford, Oxford, UK.
Somya AgrawalTesting Operations (COVID 19), UK Health Security Agency, UK.
Hannah FordhamTesting Operations (COVID 19), UK Health Security Agency, UK.
Tom FowlerClinical and Public Health Group, UK Health Security Agency, UK.
Alex SienkiewiczUK Health Security Agency, Porton, UK.
Ann Sarah WalkerOxford University Hospitals NHS Foundation Trust, Oxford, UK.
Sir John BellNuffield Department of Medicine, University of Oxford, Oxford, UK.
Richard VipondUK Health Security Agency, Porton, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: In August 2020, Public Health England and Oxford University were commissioned to design and deliver (with NHS Test and Trace, NHSTT) a rapid evaluation programme of antigen Lateral Flow Devices (LFDs) for SARS-CoV-2 for mass community testing. Methods: A three-phase evaluation process was established: 1) desktop review of kits including claimed performance and supply; 2) laboratory testing with laboratory-grown SARS-CoV-2 virus and SARS-CoV-2 virus PCR negative volunteer samples; and 3) larger-scale laboratory testing of SARS-CoV-2 PCR positive and negative clinical samples. Variant of Concern (VOC) identification in the UK (December 2020), expanded laboratory methodology. Processes also evolved to improve workflow (irradiated viral stocks, dilution matrices, sample volumes, and replicates). Findings: Overall, 1017 kits were screened at phase 1, 185 kits tested at phase 2 and 91 at phase 3. Sixteen kits failed phase 3 due to poor performance and eight more failed to detect VOC satisfactorily. Sixty-four kits were redesigns of previously failed kits. The overall pass rate for the laboratory evaluation was 35% and 5 kits were procured for the UK National Covid 19 Testing Programme. Interpretation: The evaluation results had potential, time limited commercially sensitive aspects, and public sharing was limited to kits passing phase 3. Until now, the full data set has not been published. Over 2.5 billion self-test kits were deployed by the UK government following purchasing decisions informed by this work. We offer a potential blueprint for future evaluation programmes that might be required to assess LFDs to detect cases of a pandemic novel pathogen. Funding: This study was funded by UK Department of Health and Social Care (UKHSA); UK Health Security Agency (formerly Public Health England and the National Health Service Test and Trace); and the University of OxfordNIHRBiomedical Research Centre.

Indexed as

CoronavirusLaboratory evaluationLateral flow deviceLFDMass-testingPandemicPublic healthSARS-CoV-2

Identifiers

PMID41054442
PMCPMC12496213

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.