ArticleArthroplasty (London, England)2025
Surgical accuracy of open platform image-based robotic-assisted total knee arthroplasty across different implants: a multicentre trial.
Article in Arthroplasty (London, England), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundImplant malalignment in total knee arthroplasty (TKA) correlates with poor outcomes, and robotic-assisted systems aim to improve precision. While closed-platform robotic systems dominate the market, their restriction to proprietary implants limits surgical flexibility. This study evaluates the radiological accuracy of an open-platform robotic system (Yuanhua KUNWU) across four TKA implant designs.
methodsA multi-centre retrospective analysis of 129 robotic-assisted TKAs (Zhengtian Irene, n = 60; DePuy Synthes Attune, n = 32; Zimmer Biomet Persona, n = 20; Smith & Nephew Legion, n = 17) was conducted. Patients with end-stage osteoarthritis (Kellgren-Lawrence grade 3-4) were included, while those with prior knee surgery or complex anatomy were excluded (n = 15). A total of 114 pre-operative and post-operative alignment (hip-knee-ankle angle [HKA], femoral and tibial component coronal angles [FCCA, TCCA], posterior tibial slope [PTS]) were measured on radiographs by two independent reviewers. Interobserver reliability (intra-class correlation [ICC], Cronbach's α) and deviations from planned alignment (paired t-tests) were analysed. Acceptability was defined as ≤ 3° deviation.
resultsInterobserver reliability was excellent (ICC > 0.77, Cronbach's α > 0.87 for all parameters). Mean post-operative deviations from planned alignment were clinically small: HKA (+1.32°, P < 0.001), FCCA (-0.55°, P < 0.001), TCCA (+0.19°, P = 0.097), and PTS (-0.42°, P = 0.018). All mean differences were within the 3° acceptability threshold. Subgroup analysis of pre- and post-operative alignment between implant types also showed deviations of < 3°.
conclusionsThe KUNWU open-platform robotic system achieved high radiological accuracy across four implant designs, with alignment deviations < 1.5°. This suggests open-platform robotics can provide implant versatility without compromising precision. Further studies regarding the assessment of long-term clinical and patient-reported outcomes and comparison with closed-platform systems are warranted.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials