Evidence map›Paper›PMID 41053897›Full record

ArticleArthroplasty (London, England)2025

Surgical accuracy of open platform image-based robotic-assisted total knee arthroplasty across different implants: a multicentre trial.

Michael Tim-Yun Ong, Chuan He, Wei Chai, Rex Wang-Fung Mak, Cham-Kit Wong, Gloria Yan-Ting Lam, Tsz Lung Choi, Patrick Shu-Hang Yung

Abstract read
In one paragraph

Article in Arthroplasty (London, England), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Michael Tim-Yun OngChinese University of Hong Kong, Hong Kong SAR, China. michael.ong@cuhk.edu.hk.
Chuan HeRuijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China. drhechuan@sina.com.
Wei ChaiFourth Medical Centre of Chinese PLA General Hospital, Beijing, 100089, China.
Rex Wang-Fung MakPrince of Wales Hospital, Hong Kong SAR, China.
Cham-Kit WongAlice Ho Miu Ling Nethersole Hospital, Hong Kong SAR, China.
Gloria Yan-Ting LamAlice Ho Miu Ling Nethersole Hospital, Hong Kong SAR, China.
Tsz Lung ChoiAlice Ho Miu Ling Nethersole Hospital, Hong Kong SAR, China.
Patrick Shu-Hang YungChinese University of Hong Kong, Hong Kong SAR, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundImplant malalignment in total knee arthroplasty (TKA) correlates with poor outcomes, and robotic-assisted systems aim to improve precision. While closed-platform robotic systems dominate the market, their restriction to proprietary implants limits surgical flexibility. This study evaluates the radiological accuracy of an open-platform robotic system (Yuanhua KUNWU) across four TKA implant designs.

methodsA multi-centre retrospective analysis of 129 robotic-assisted TKAs (Zhengtian Irene, n = 60; DePuy Synthes Attune, n = 32; Zimmer Biomet Persona, n = 20; Smith & Nephew Legion, n = 17) was conducted. Patients with end-stage osteoarthritis (Kellgren-Lawrence grade 3-4) were included, while those with prior knee surgery or complex anatomy were excluded (n = 15). A total of 114 pre-operative and post-operative alignment (hip-knee-ankle angle [HKA], femoral and tibial component coronal angles [FCCA, TCCA], posterior tibial slope [PTS]) were measured on radiographs by two independent reviewers. Interobserver reliability (intra-class correlation [ICC], Cronbach's α) and deviations from planned alignment (paired t-tests) were analysed. Acceptability was defined as ≤ 3° deviation.

resultsInterobserver reliability was excellent (ICC > 0.77, Cronbach's α > 0.87 for all parameters). Mean post-operative deviations from planned alignment were clinically small: HKA (+1.32°, P < 0.001), FCCA (-0.55°, P < 0.001), TCCA (+0.19°, P = 0.097), and PTS (-0.42°, P = 0.018). All mean differences were within the 3° acceptability threshold. Subgroup analysis of pre- and post-operative alignment between implant types also showed deviations of < 3°.

conclusionsThe KUNWU open-platform robotic system achieved high radiological accuracy across four implant designs, with alignment deviations < 1.5°. This suggests open-platform robotics can provide implant versatility without compromising precision. Further studies regarding the assessment of long-term clinical and patient-reported outcomes and comparison with closed-platform systems are warranted.

Indexed as

Implant alignmentOpen-platform total knee arthroplastyRadiological accuracyRobotic-assisted total knee arthroplastyTotal knee arthroplasty

Identifiers

PMID41053897
PMCPMC12502208

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.