Evidence map›Paper›PMID 41052220›Full record

ArticlePloS one2025

Laser-based pulse oximetry eliminates pigmentation effects on oxygen saturation measurements: A pilot study.

Jonas A Pologe, Nathan K You, Mark Blumstein, Kristine L Snyder, William W Hay

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jonas A PologeResearch and Development, Zynex Monitoring Solutions, Boulder, Colorado, United States of America.ORCID https://orcid.org/0009-0003-7289-762X
Nathan K YouResearch and Development, Zynex Monitoring Solutions, Boulder, Colorado, United States of America.ORCID https://orcid.org/0009-0006-0877-9532
Mark BlumsteinResearch and Development, Zynex Monitoring Solutions, Boulder, Colorado, United States of America.
Kristine L SnyderResearch and Development, Zynex Monitoring Solutions, Boulder, Colorado, United States of America.
William W HayDenver, Colorado, United States of America.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAlmost since its introduction, pulse oximetry has been plagued by inaccuracy associated with pigmentation, whether from fingernail polishes or melanin. The presence of melanin in the optical path of a pulse oximetry sensor has been shown to artifactually increase oxygen saturation measurements which can result, clinically, in occult hypoxemia and misdiagnoses.

methodsThis report describes the theoretical basis for this inaccuracy and presents results from both a benchtop study and a clinical study testing the effects of pigmentation on conventional LED-based pulse oximetry compared to laser-based pulse oximetry. The clinical portion of this study was performed on 18 consenting participants, nine darkly pigmented and nine lightly pigmented, to assess the ability of laser-based pulse oximetry to eliminate this dangerous pigmentation bias. The clinical study directly compared oxygen saturation readings on laser-based pulse oximeters to readings performed on two different LED-based pulse oximeters. All measurements were compared to invasive reference laboratory measurements performed on arterial blood samples. We hypothesized that monochromatic light sources used in laser-based pulse oximetry would make this new technology insensitive to pigmentation bias.

resultsThe clinical portion of this study showed significantly greater (p < 0.001) measurement error (variance) for the two LED-based pulse oximeters (5.48 and 5.47) compared to laser-based pulse oximetry (3.54), when analyzed for all participants. The bias differences in oxygen saturation measurements by the LED-based pulse oximeters, when made on lightly versus darkly pigmented participants compared to invasive reference measurements, accounts for most of the increase in measurement error.

conclusionsBy combining theoretical development, experimental benchtop testing, and a clinical study, this research explains and demonstrates that the wide spectral bandwidth of LEDs is the root cause of pigmentation bias in commercially available LED-based pulse oximetry and validates the ability of narrow-band laser-based pulse oximetry to eliminate this pigmentation bias.

Indexed as

LasersOximetryOxygenOxygen SaturationPigmentationAdultFemaleHumansMaleMelaninsMiddle AgedPilot ProjectsSkin PigmentationMelaninsOxygen

Identifiers

PMID41052220
PMCPMC12500151

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.