Accuracy of iodine quantification and CT numbers using split-filter dual-energy CT: influence of phantom diameter.

Masato Kiriki, Maiko Kishigami, Toshiyuki Sakai, Takahiro Minamoto

Abstract read
PubMed Publisher
In one paragraph

Article in Physical and engineering sciences in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Masato KirikiDepartment of Radiological Technology, Hyogo Medical University Hospital, 1-1 Mukogawa-cho, Nishinomiya, Hyogo, 663-8501, Japan. ma-kiriki@hyo-med.ac.jp.ORCID http://orcid.org/0009-0009-0818-0177
Maiko KishigamiDepartment of Advanced Medical Physics, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan.
Toshiyuki SakaiDepartment of Radiological Technology, Hyogo Medical University Hospital, 1-1 Mukogawa-cho, Nishinomiya, Hyogo, 663-8501, Japan.
Takahiro MinamotoDepartment of Radiological Technology, Hyogo Medical University Hospital, 1-1 Mukogawa-cho, Nishinomiya, Hyogo, 663-8501, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Dual-energy computed tomography (DECT) generates virtual monochromatic images (VMI) and material decomposition images (MDI), facilitating enhanced tissue contrast and quantitative material assessment. However, the accuracy of these measurements may be influenced by object size due to beam hardening and associated spectral changes. To evaluate the impact of object size on the accuracy of iodine quantification and CT numbers in virtual monochromatic images (VMI) using split-filter dual-energy CT (SFDE), and to compare its performance with sequential acquisition dual-energy CT (SADE). CT scans were performed on phantoms with diameters ranging from 16 to 36 cm using both SFDE and SADE techniques. Virtual monochromatic images and material decomposition images were generated. CT numbers and iodine concentrations were measured from embedded iodine rods, and relative errors were calculated using the 16 cm phantom as a reference. CT numbers in VMI obtained from SFDE exhibited increasing variability with larger phantom sizes, particularly at both low and high energy levels. Iodine quantification errors with SFDE exceeded 10% in all phantom sizes and reached approximately 60% in the 36 cm phantom. In contrast, SADE consistently maintained measurement errors within 10%. Object size significantly influences the accuracy of CT numbers and iodine quantification using SFDE, with larger phantoms showing marked overestimation. These results suggest that careful interpretation is necessary when applying SFDE-based quantitative imaging in patients with larger object sizes.

Indexed as

IodinePhantoms, ImagingTomography, X-Ray ComputedIodineDual energy CTMaterial decomposition imageSplit-filterVirtual monochromatic image

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.