Evidence map›Paper›PMID 41051471›Full record

ArticlePhysical and engineering sciences in medicine2026

Monitoring of respiration and cardiorespiratory interactions from multichannel seismocardiography signals.

Jessica Centracchio, Salvatore Parlato, Samuel E Schmidt, Paolo Bifulco, Daniele Esposito, Emilio Andreozzi

Abstract read
In one paragraph

Article in Physical and engineering sciences in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Wearable Flexible Sensors for Cardiovascular Disease Monitoring.Advanced materials (Deerfield Beach, Fla.) · 2026
    Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jessica CentracchioDepartment of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21, 80125, Naples, Italy.ORCID http://orcid.org/0000-0003-3422-8727
Salvatore ParlatoDepartment of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21, 80125, Naples, Italy.ORCID http://orcid.org/0009-0000-9314-5126
Samuel E SchmidtDepartment of Health Science and Technology, Aalborg University, Selma Lagerløfs Vej 249, 9260, Gistrup, Aalborg, Denmark.ORCID http://orcid.org/0000-0002-0917-634X
Paolo BifulcoDepartment of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21, 80125, Naples, Italy.ORCID http://orcid.org/0000-0002-9585-971X
Daniele EspositoDepartment of Information and Electrical Engineering and Applied Mathematics, University of Salerno, Via Giovanni Paolo II, 132, 84084, Fisciano, Italy.ORCID http://orcid.org/0000-0003-0716-8431
Emilio AndreozziDepartment of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21, 80125, Naples, Italy. emilio.andreozzi@unina.it.ORCID http://orcid.org/0000-0003-4829-3941

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Seismocardiography (SCG) uses accelerometers to record cardiac-induced accelerations of the chest wall. Cardiorespiratory interactions cause changes in amplitude and morphology of the SCG signals. Accelerometers can also directly monitor respiration by tracking thoracic inclination. This study thoroughly investigated the influence of accelerometer placement on the monitoring accuracy of respiration and cardiorespiratory interactions from SCG signals. Simultaneous recordings acquired by 16 accelerometers and a respiration belt placed onto 9 subjects' chests were analyzed. Respiratory signals were estimated considering: (a) chest inclination, (b) amplitude modulation (AM) and (c) morphological changes of SCG signals for each sensor location. For the first time in literature, a continuous description of respiratory-induced changes in SCG morphology was obtained via a morphological similarity index (MSi). The performance of respiratory acts detection and inter-breath intervals (IBIs) estimation was evaluated against the concurrent reference respiration signal. High accuracy was achieved in all three kinds of respiratory signals, with average sensitivity and positive predictive value of 95.8% and 95.5% for chest inclination, 85.9% and 84.4% for AM, 94.3% and 95.7% for MSi. Moreover, IBIs measurements showed non-significant biases and limits of agreement of about ± 0.8 s for chest inclination and MSi, and ± 1 s for AM. Performance achieved by chest inclination and MSi appeared not much influenced by sensor location, while AM showed higher variations. Information on breathing and cardiorespiratory interactions can be accurately obtained via SCG on multiple sites on the chest.

Indexed as

RespirationSignal Processing, Computer-AssistedAccelerometryAdultFemaleHumansMaleMonitoring, PhysiologicYoung AdultAccelerometerCardiac monitoringCardiorespiratory interactionsRespirationSeismocardiography

Identifiers

PMID41051471
PMCPMC12987811

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.