Performance Evaluation of Constant Field and Traveling Wave-Based Structures for Lossless Ion Manipulations Devices Coupled to Mass Spectrometry.
Article in Journal of the American Society for Mass Spectrometry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Resolving Isomeric Structures in Natural Complex Carbohydrates: A Comparative Study of SLIM and Cyclic Ion Mobility Platforms.Rapid communications in mass spectrometry : RCM · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
The performances of three prototype structures for lossless ion manipulations IMS mass spectrometer (SLIM IMS-MS) are evaluated. The instrument was constructed by replacing the drift tube of an Agilent 6560 with either traveling wave (TW) or constant field (CF) based SLIM modules of nearly identical length. The TW-SLIM module contains a 79.4 cm straight path and a 10 m serpentine path. The evaluation of these systems enabled the direct determination of performance differences associated with the drift tube replacement by the SLIM devices. The evaluation included comparing the resolution, resolving power, transmitted mass range, and collisional cross-section (CCS) accuracy relative to its drift tube counterpart for each device/path. Results indicated that the 79.4 cm CF-SLIM displayed comparable performance to the drift tube while the 79.4 cm TW-SLIM path provided ∼25% higher resolution and resolving powers (