Evidence map›Paper›PMID 41050626›Full record

ArticleIEEE transactions on radiation and plasma medical sciences2025

A Time-Walk and Timing-Shift Correction Method for Dual-Ended Readout TOF-DOI PET Detectors.

Haibo Wang, Jiahao Xie, Jinyi Qi, Simon R Cherry, Junwei Du

Abstract read
In one paragraph

Article in IEEE transactions on radiation and plasma medical sciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Development of Whole-Body TOF-DOI PET Detector Using Dual-Ended Readout Method.IEEE transactions on instrumentation and measurement · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Haibo WangDepartment of Biomedical Engineering, University of California at Davis, Davis, CA 95616 USA.
Jiahao XieDepartment of Biomedical Engineering, University of California at Davis, Davis, CA 95616 USA.
Jinyi QiDepartment of Biomedical Engineering, University of California at Davis, Davis, CA 95616 USA.
Simon R CherryDepartment of Biomedical Engineering, University of California at Davis, Davis, CA 95616 USA.
Junwei DuDepartment of Biomedical Engineering, University of California at Davis, Davis, CA 95616 USA.

Funding

A 0.5 mm resolution total-body small-animal PETR01EB031961 · NIBIB · UNIVERSITY OF CALIFORNIA AT DAVIS · PI DU, JUNWEI · 2022 to 2025
$2.6M
Maximizing sensitivity for ultra-low dose PET imagingR01EB028806 · NIBIB · UNIVERSITY OF CALIFORNIA AT DAVIS · PI DU, JUNWEI · 2020 to 2024
$2.3M
NIBIB NIH HHS R01 EB028806NIBIB NIH HHS R01 EB031961
6 · The paper itself

Abstract

Positron emission tomography (PET) detectors suffer from time-walk when the leading edge discriminator is employed for timing pick-off as well as a timing-shift when thick crystals are utilized due to the depth-of-interaction (DOI) effect. In this study, a combined time-walk and timing-shift correction method was proposed for dual-ended readout PET detectors. To evaluate the proposed method, a pair of dual-ended readout PET detectors was constructed. Each detector was based on two Hamamatsu S14161-3050-08 silicon photomultiplier (SiPM) arrays coupled to both ends of an

Indexed as

DOIDual-Ended ReadoutPETTime-Walk CorrectionTiming-Shift Correction

Identifiers

PMID41050626
PMCPMC12493018

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.