ArticleJSES international2025
Artificial intelligence to automatically measure on radiographs the postoperative positions of the glenosphere and pivot point after reverse total shoulder arthroplasty.
Article in JSES international, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Artificial Intelligence in Arthroplasty: A Comprehensive Structured Critical Review and Descriptive Evidence Map of Validation, Uncertainty, and Workflow Integration.Bioengineering (Basel, Switzerland) · 2026Review
- Artificial intelligence for postoperative plain radiographic assessment after reverse total shoulder arthroplasty: current evidence, clinical readiness, and limitations.Clinics in shoulder and elbow · 2026Article
- Artificial Intelligence Applications in Implant Positioning, Dislocation Risk Prediction, and Surgical Indications in Orthopaedic Surgery.Bioengineering (Basel, Switzerland) · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Radiographic evaluation of the implant configuration after reverse total shoulder arthroplasty (rTSA) is a time-consuming task that is frequently subject to interobserver disagreement. Deep learning (DL) artificial intelligence algorithms have previously demonstrated high accuracy when analyzing relevant angles to determine rTSA distalization and lateralization, as well as glenoid inclination and humeral alignment. The goal of this study is to build on this existing work to automatically measure the postoperative radiographic location of the glenosphere center of rotation (GCR) and the pivot point (PP) in reference to the scapula. Methods: A total of 417 primary rTSA postoperative anteroposterior radiographs were retrieved and utilized for this study. Five measurements were designed and manually performed by 3 observers: (1) the medial position and (2) the inferior position of the geometric center of rotation of the glenosphere (glenosphere center of rotation medialization [GCRm] and glenosphere center of rotation inferiorization [GCRi], respectively) relative to the most lateral aspect of the inferior acromion, as well as (3) the projection of the PP to GCR vector on the fossa line (PP projection), (4) the distance between GCR and glenoid (GCR-glenoid distance), and (5) the overall glenoid lateral offset (GLO). Subsequently, a DL algorithm was developed to automatically segment the radiograph and perform the same measurements described above. All measurements were corrected for radiographic magnification using the known glenosphere diameter for each shoulder. Intraclass Correlation Coefficients (ICCs) were calculated to assess interobserver and DL-human agreements on all measurements. Results: The DL algorithm achieved an average Dice Coefficient of 0.86, indicating good segmentation accuracy. The ICCs (95% confidence interval) amongst human observers were 0.86 (0.81-0.90) for the GCRm, 0.93 (0.9-0.95) for the GCRi, 0.95 (0.92-0.96) for the PP projection, 0.85 (0.79-0.89) for GCR-glenoid distance, and 0.92 (0.88-0.95) for GLO. The ICCs between the DL-derived measurements and the average of manual measurements were 0.95 (0.92-0.96) for the GCRm, 0.90 (0.84-0.93) for the GCRi, 0.96 (0.94-0.98) for the PP projection, 0.91 (0.87-0.94) for GCR-glenoid distance, and 0.92 (0.88-0.95) for GLO. The DL algorithm automatically analyzed each testing image in 2 seconds. Conclusion: The developed DL algorithm can automatically measure the location of the glenosphere geometric center of rotation and the location of the PP on postoperative radiographs obtained after primary rTSA. Agreement between DL-derived measures and those from human observers was high. This DL algorithm adds to the armamentarium of tools available for automatic assessment of final implant position on radiographs after rTSA.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.