Evidence map›Paper›PMID 41047917›Full record

ArticleJournal of clinical laboratory analysis2025

Clinical Application of Using Diffusion-Based Wasserstein Generative Adversarial Network for Morphologic Analysis of Blood Cells.

Hyun-Young Kim, Emmanuel Edward Ngasa, Hee-Jin Kim, Boram Kim, Gyujin Lim, Chang-Hun Park, Hyeon Jeong Kwon, Mi-Ae Jang, Jiyoung Woo

Abstract read
In one paragraph

Article in Journal of clinical laboratory analysis, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Hyun-Young KimDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0003-0553-7096
Emmanuel Edward NgasaDepartment of Future Convergence Technology, Soonchunhyang University, Asan, Korea.ORCID https://orcid.org/0000-0002-3245-7983
Hee-Jin KimDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Boram KimDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-5695-8902
Gyujin LimDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Chang-Hun ParkDepartment of Laboratory Medicine and Genetics, Soonchunhyang University Medical School of College, Soonchunhyang University Bucheon Hospital, Bucheon, Korea.ORCID https://orcid.org/0000-0002-0412-3732
Hyeon Jeong KwonCenter for Clinical Medicine, Samsung Biomedical Research Institute, Samsung Medical Center, Seoul, Korea.
Mi-Ae JangDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-6558-5236
Jiyoung WooDepartment of Future Convergence Technology, Soonchunhyang University, Asan, Korea.

Funding

Korean Society of Hematology ICKSH-2021-6National Research Foundation of Korea RS-2025-00519514
6 · The paper itself

Abstract

backgroundMorphologic analysis of peripheral blood smears is essential for diagnosing hematologic diseases and patient management. Although manual microscopy is the traditional gold standard, it is time-consuming and subjective. Digital morphology analyzers have improved automation and accuracy; however, challenges remain, particularly in classifying certain cell types. Recently, the diffusion-based Wasserstein generative adversarial network with gradient penalty (DWGAN-GP) showed potential by enhancing image quality and addressing data imbalance. We aim to investigate the accuracy of blood cell classification using the DWGAN-GP model.

methodsIn this study, the DWGAN-GP model in conjunction with the EfficientNetB3 classification model was evaluated using 78,494 peripheral blood cell images. Samples were collected from patients with normal and abnormal hematologic conditions. Data were balanced by augmenting underrepresented classes with synthetic images, resulting in equal representation across 13 cell classes. Performance was compared with PBIA (ANI Co., Suwon, Korea), a commercial digital morphology analyzer.

resultsDWGAN-GP augmentation significantly improved classification accuracy of the EfficientNetB3 model to 97.74% with an F1-score of 91.13%. This result surpassed both the unbalanced dataset (accuracy 95.68%, F1-score 82.12%) and PBIA system (accuracy 95%). Notably, improvements were significant in minority classes such as blasts and myelocytes, which are critical in diagnosing leukemia.

conclusionIncorporating synthetic data using DWGAN-GP significantly enhanced model performance and addressed class imbalance. This method shows promise for more accurate and consistent blood cell classification, offering potential improvements in clinical diagnostics for hematologic disorders.

Indexed as

Blood CellsImage Processing, Computer-AssistedNeural Networks, ComputerGenerative Adversarial NetworksHumansblood cellsclassificationdeep learningdiffusion modelgenerative adversarial networkhematologic diseases

Identifiers

PMID41047917
PMCPMC12640791

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.