Evidence map›Paper›PMID 41047378›Full record

Trial reportCardiovascular and interventional radiology2025

Efficacy of an X-Ray Protective Drape in Reducing Operator Radiation Dose in Transfemoral Arterial Liver Interventions: a Randomized-Controlled Trial.

Lawrence Bonne, Niki Bergans, Keir McCutcheon, Annouschka Laenen, Ria Bogaerts, Jeroen Vanheule, Johan Bennett, Lesley Cockmartin, Hilde Bosmans, Walter Desmet and 1 more

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Cardiovascular and interventional radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Lawrence BonneDepartment of Radiology, University Hospitals Leuven, Herestraat 49, 3000, Louvain, Belgium. lawrence.bonne@uzleuven.be.ORCID http://orcid.org/0000-0001-9610-280X
Niki BergansDepartment of Oncology, University Hospitals Leuven, Louvain, Belgium.
Keir McCutcheonDepartment of Cardiovascular Medicine, University Hospitals Leuven, Louvain, Belgium.
Annouschka LaenenInteruniversity Institute for Biostatistics and Statistical Bioinformatics, Louvain, Belgium.
Ria BogaertsRadiation Protection and Dosimetry Service of the Department of Health, Safety and Environment, University Hospitals Leuven, Louvain, Belgium.
Jeroen VanheuleRadiation Protection and Dosimetry Service of the Department of Health, Safety and Environment, University Hospitals Leuven, Louvain, Belgium.
Johan BennettDepartment of Cardiovascular Medicine, University Hospitals Leuven, Louvain, Belgium.
Lesley CockmartinDepartment of Radiology, University Hospitals Leuven, Herestraat 49, 3000, Louvain, Belgium.
Hilde BosmansDepartment of Radiology, University Hospitals Leuven, Herestraat 49, 3000, Louvain, Belgium.
Walter DesmetDepartment of Cardiovascular Medicine, University Hospitals Leuven, Louvain, Belgium.
Geert MaleuxDepartment of Radiology, University Hospitals Leuven, Herestraat 49, 3000, Louvain, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeInterventional radiologists are among the healthcare professionals most exposed to ionizing scatter radiation. A 0.5 mm lead equivalent X-ray protective drape (MXPD, Mavig, Germany) was introduced to reduce operator radiation dose and has demonstrated efficacy during cardiac interventions. This study evaluates the efficacy of the MXPD during transfemoral liver interventions. MATERIALS &

methodsA single-center randomized controlled study was conducted to compare operator radiation exposure during transfemoral liver interventions (n = 100) with and without the MXPD. Primary outcome was the ratio of the combined operator radiation dose values-measured at the chest, eyes and both hands and normalized to the respective dose area products - between MXPD and control groups. Secondary outcomes included the ratios in operator radiation doses measured for the individual dosimeter locations.

resultsThe MXPD group showed a significantly lower normalized radiation dose per DAP (mean reduction 0.31 µSv; 95% CI 0.083-0.536, p = 0.009), representing a 43% reduction. The effect of the drape was the highest for the whole-body dose measured above the lead apron (55% reduction, p = 0.10), the left hand finger dose (43%, p = 0.20) and the eye lens dose estimated at the left temple (63%, p = 0.10) and in between the eyes (47%, p = 0.10).

conclusionThe MXPD can effectively reduce operator radiation dose during transfemoral arterial liver interventions, offering a practical adjunct to standard protective measures. LEVEL OF EVIDENCE: Level 1b, Randomized Controlled Trial.

Indexed as

LiverOccupational ExposureRadiation DosageRadiation ExposureRadiation ProtectionRadiography, InterventionalAgedFemaleFemoral ArteryHumansMaleMiddle AgedPelvic drapesRadiation protectionTransarterial liver interventions

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked