Evidence map›Paper›PMID 41044701›Full record

ArticleBMC surgery2025

A convenient and self-adjustable laparoscopic intracorporeal pringle maneuver using He's belt.

Huilan Zeng, Jiaqiang Mo, Sili Lu, Qing Ye, Zhangyuanzhu Liu, Jianyi Wang, Yanbei Yin, Peiying Zhong, Ting Xiao, Yanjiao Hu and 3 more

Abstract read
In one paragraph

Article in BMC surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Huilan Zeng *Department of Hepatobiliary Surgery, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, 510120, People's Republic of China.
Jiaqiang Mo *Department of Hepatobiliary Surgery, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, 510120, People's Republic of China.
Sili LuDepartment of Hepatobiliary Surgery, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, 510120, People's Republic of China.
Qing YeDepartment of Hepatobiliary Surgery, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, 510120, People's Republic of China.
Zhangyuanzhu LiuDepartment of Hepatobiliary Surgery, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, 510120, People's Republic of China.
Jianyi WangDepartment of Hepatobiliary Surgery, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, 510120, People's Republic of China.
Yanbei YinDepartment of Hepatobiliary Surgery, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, 510120, People's Republic of China.
Peiying ZhongDepartment of Hepatobiliary Surgery, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, 510120, People's Republic of China.
Ting XiaoDepartment of Hepatobiliary Surgery, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, 510120, People's Republic of China.
Yanjiao HuDepartment of Hepatobiliary Surgery, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, 510120, People's Republic of China.
Lijun LinDepartment of Hepatobiliary Surgery, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, 510120, People's Republic of China.
Jianxin PengDepartment of Hepatobiliary Surgery, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, 510120, People's Republic of China.
Junming HeDepartment of Hepatobiliary Surgery, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, 510120, People's Republic of China. hejunming0101@sina.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study introduces an intracorporeal Pringle maneuver (PM) using He’s belt for laparoscopic hepatectomy.

methodsHe’s belt, a silicone belt featuring a hole in the tail and eight cogs in the body, was placed in the abdominal cavity. The head and body of He’s belt were pulled out through the tail hole to form a ring encircling the hepatoduodenal ligament. We conducted laparoscopic hepatectomy with PM maneuver by He’s belt for 47 patients between January 2024 and June 2024.

resultThe PM maneuver using He’s belt can be easily performed, adjusted, and released without requiring additional Hemoclips. For the 47 patients, the median operative time was 121 min. The median Pringle time was 21 min. The median blood loss was 50 ml. None of the patients required intraoperative blood transfusion.

conclusionThe PM maneuver using He’s belt is a safe, convenient, and self-adjustable method that provides effective inflow control for laparoscopic hepatectomy.

Indexed as

HepatectomyLaparoscopyAdultAgedBlood Loss, SurgicalEquipment DesignHumansMaleMiddle AgedOperative Time

Identifiers

PMID41044701
PMCPMC12495834

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.