Evidence map›Paper›PMID 41044555›Full record

ArticleBMC health services research2025

Analysis and actions after laboratory errors in a Chinese university hospital.

Ying Guo, Wei Dai, Yongmei Jiang, Xiaojuan Liu

Abstract read
In one paragraph

Article in BMC health services research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ying GuoDepartment of Laboratory Medicine, West China Second University Hospital, Sichuan University, No. 20, Section 3, Ren Min Nan Lu, Chengdu, 610041, Sichuan, P.R. China.
Wei DaiDepartment of Laboratory Medicine, West China Second University Hospital, Sichuan University, No. 20, Section 3, Ren Min Nan Lu, Chengdu, 610041, Sichuan, P.R. China.
Yongmei JiangDepartment of Laboratory Medicine, West China Second University Hospital, Sichuan University, No. 20, Section 3, Ren Min Nan Lu, Chengdu, 610041, Sichuan, P.R. China.
Xiaojuan LiuDepartment of Laboratory Medicine, West China Second University Hospital, Sichuan University, No. 20, Section 3, Ren Min Nan Lu, Chengdu, 610041, Sichuan, P.R. China. maggielxj1979@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDiagnostic errors pose a critical threat to patient safety, heavily relying on accurate laboratory medicine. However, research specifically addressing laboratory errors (LEs) remains limited globally. This study aimed to categorize LEs, identify their root causes, and develop targeted interventions within a large, specialized hospital in China, where systemic factors amplify their potential impact.

methodsA retrospective quality improvement study was conducted in the ISO 15,189 and CAP-accredited Department of Medical Laboratory at a women and children's hospital. Eighty-three documented LEs (51 general, 32 transfusion-specific) from March 2016 to April 2023 were analyzed. Errors were captured via internal incident reporting and hospital risk management systems. LEs were classified using five criteria: responsibility attribution (exclusively lab, extra-lab, conjoint, undetermined), testing phase (preanalytical, analytical, postanalytical), error type, preventability (using a cognitive psychology framework: cognitive vs. noncognitive), and patient impact. Root cause analysis and corrective actions were tracked.

resultsAmong the 51 general LEs, the preanalytical phase was most error-prone (51.0%), primarily due to specimen collection (29%) and request procedure errors (22%). Analytical (4%) and postanalytical (18%) phases had fewer errors. Responsibility analysis showed 20% exclusively lab-originated, 60% extra-lab-originated, and 16% conjoint. Cognitive errors dominated preventable incidents. Environmental/infrastructure (6%) and Laboratory Information System (LIS) errors (14%) were significant concerns. Separately, among 32 transfusion-related errors, clinical physicians bore primary responsibility in 51%, with common issues being improper specimen collection (22%) and non-evidence-based orders (16%). Corrective actions (e.g., workflow optimization, staff training, improved communication, LIS upgrades like an electronic critical value notification system, facility relocation) led to significant reductions in preanalytical errors over time. Improvements were achieved cost-effectively.

conclusionPreanalytical errors are the most prevalent LEs, often originating outside the laboratory. Cognitive errors are highly preventable. Implementing targeted interventions based on systematic error classification and root cause analysis-including technological solutions (e.g., electronic alerts, LIS improvements), workflow simplification, enhanced training (especially for non-laboratory personnel in transfusion contexts), and interdepartmental communication-significantly reduces LEs and enhances laboratory quality management. Continuous monitoring and context-specific strategies are crucial, especially in large healthcare systems. Study limitations include potential underreporting and limited generalizability beyond specialized women and children's hospital settings.

Indexed as

Diagnostic ErrorsHospitals, UniversityLaboratories, HospitalChinaFemaleHumansMedical ErrorsPatient SafetyQuality ImprovementRetrospective StudiesRisk ManagementRoot Cause AnalysisCorrective actionLaboratory-related errorsQuality improvement

Identifiers

PMID41044555
PMCPMC12495776

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.