Evidence map›Paper›PMID 41044493›Full record

ArticleBMC surgery2025

An investigation to the clinical application of personalized 3D printed guides combined with preoperative virtual iliosacral screws for the management of posterior pelvic ring injury.

Peishuai Zhao, Leyu Liu, Jiaqiang Chen, Renjie Li, Xiaopan Wang, Min Wu

Abstract read
In one paragraph

Article in BMC surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Peishuai ZhaoDepartment of Orthopaedics, The First Affiliated Hospital of Bengbu Medical University, Bengbu, Anhui, China.
Leyu LiuDepartment of Orthopaedics, The First Affiliated Hospital of Bengbu Medical University, Bengbu, Anhui, China.
Jiaqiang ChenDepartment of Orthopaedics, The First Affiliated Hospital of Bengbu Medical University, Bengbu, Anhui, China.
Renjie LiDepartment of Orthopaedics, The First Affiliated Hospital of Bengbu Medical University, Bengbu, Anhui, China.
Xiaopan WangDepartment of Orthopaedics, The First Affiliated Hospital of Bengbu Medical University, Bengbu, Anhui, China.
Min WuDepartment of Orthopaedics, The First Affiliated Hospital of Bengbu Medical University, Bengbu, Anhui, China. wumin197010@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe use of percutaneous iliosacral screws for the treatment of unstable pelvic ring injuries is highly challenging and typically requires fluoroscopic or navigational guidance. This study aims to introduce a novel 3D-printed guide plate for the safe insertion of iliosacral screws during surgery and to evaluate the effectiveness and safety of this technique.

methodsA retrospective analysis was conducted on patients who underwent surgery for unstable posterior pelvic ring injuries at our trauma center between January 2020 and May 2023. The surgeries were performed by the same group of surgeons. Patients were divided into two groups based on different surgical methods: the guide plate group (GP group, n = 14) and the conventional surgery group (CS group, n = 17). Data on gender, cause of injury, age, sacral dysmorphism, fracture classification, time for each screw insertion, fluoroscopy time for each screw, postoperative screw position grading, follow-up duration, and fracture reduction quality at the last follow-up were recorded.

resultsThe CS group included 17 patients (8 males and 9 females) with a mean age of 42.6 ± 13.4 years; the GP group included 14 patients (6 males and 8 females) with a mean age of 40.4 ± 13.1 years. There were no statistically significant differences between the two groups in terms of gender, age, cause of injury, AO fracture classification, sacral dysmorphism, follow-up duration, or fracture reduction quality. A total of 42 iliosacral screws were inserted in 31 patients, with 24 screws inserted in the CS group (18 in S1 and 6 in S2) and 18 screws inserted in the GP group (14 in S1 and 4 in S2). The GP group had significantly lower rates of screw misposition, fluoroscopy time per screw, and insertion time per screw compared to the CS group (5.56% vs. 25.00%; 0.31 ± 0.14 min vs. 0.91 ± 0.17 min; 17.29 ± 1.90 min vs. 25.18 ± 3.99 min). The differences in insertion time and fluoroscopy time per screw between the two groups were statistically significant (P < 0.05), while the difference in screw misposition rate was not statistically significant (P >0.05).

conclusionThe preoperative virtual screw combined with 3D guide plate technology can accurately place sacroiliac joint screws, providing a new method for percutaneous screw insertion.

Indexed as

Bone ScrewsFracture Fixation, InternalFractures, BoneIliumPelvic BonesPrinting, Three-DimensionalSacrumSurgery, Computer-AssistedAdultBone PlatesFemaleFluoroscopyHumansMaleMiddle AgedRetrospective Studies3D printingGuide plateIliosacral screwsVirtual screws

Identifiers

PMID41044493
PMCPMC12495713

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.