Evidence map›Paper›PMID 41044164›Full record

ArticleScientific reports2025

Manual measurement of SD-OCT images of hyperreflective retinal layers in acute retinal vessel occlusion is reliable, repeatable and reproducible.

Egbert Matthé, Dierk Wittig, Matthias Kuhn, Peggy Eulitz, Katharina Schoen, Dirk Sandner, Olga Furashova

Registry-linked trialAbstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03061526 (Spectral-domain Optical Coherence Tomography Findings in Retinal Vessel Occlusion - A Pilot Study of Detecting Ischemia in OCT), which is not on this map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03061526 unknown statusnot on this map

Spectral-domain Optical Coherence Tomography Findings in Retinal Vessel Occlusion - A Pilot Study of Detecting Ischemia in OCT

TypeobservationalSponsorTechnische Universität DresdenRan2017 to 2023Enrolled100ConditionsRetinal IschemiaArmsoptical coherence tomography
3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Egbert MatthéMedizinisches Versorgungszentrum Neustadt in Sachsen, Böhmische Straße 4, 01844, Neustadt in Sachsen, Germany. matthe@augen-neustadt.de.
Dierk WittigMedizinisches Versorgungszentrum Neustadt in Sachsen, Böhmische Straße 4, 01844, Neustadt in Sachsen, Germany.
Matthias KuhnInstitute for Medical Informatics and Biometry (IMB), Carl Gustav Carus Faculty of Medicine, Technische Universität Dresden, Fetscherstr. 74, 01307, Dresden, Germany.
Peggy EulitzOphthalmologists Dres. Bau und Bottesi, Bautzner Str. 66, 01099, Dresden, Germany.
Katharina SchoenOphthalmologists Dres. Wilke, Bayreuther Straße 30, 01187, Dresden, Germany.
Dirk SandnerKlinik und Poliklinik für Augenheilkunde, Carl Gustav Carus Faculty of Medicine, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany.
Olga FurashovaDepartment of Ophthalmology, Klinikum Chemnitz gGmbH, Flemmingstraße 2, 09116, Chemnitz, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To investigate the repeatability and reproducibility of manual measurements of the reflectivity of retinal layers in healthy eyes and in eyes with acute retinal vessel occlusion via spectral-domain optical coherence tomography (SD-OCT). To reflect the full spectrum of different reflectivities seen in OCT images, for each of the following conditions, exactly one patient with a healthy and an affected eye was selected: non-ischemic central retinal vein occlusion (CRVO), ischemic CRVO, incomplete, subtotal and total central retinal artery occlusion (CRAO). For all the patients, OCT images of the healthy and affected eyes were used. Each image was presented 10 times in a randomly changing sequence to all examiners (one experienced, two nonexperienced). The obtained values were analyzed via two statistical methods: Gage Repeatability & Reproducibility (Gage R&R, a measurement system analysis) and Lin's concordance correlation coefficient (Lin's CCC). The total gage R&R values were as follows: vitreous body (VB) 1.11%, innermost retinal layer (IMRL) 0.94%, middle retinal layer (MRL) 4.94%, inner retinal layer (IRL) 2.56% and outer retinal layer (ORL) 3.77%. The repeatability values were 0.79, 0.62, 2.80, 1.42 And 2.60, respectively. The reproducibility values were 0.32, 0.33, 2.41, 1.14 and 1.16, respectively. Our previously described method of manual measurement of SD-OCT images of retinal layers determining the level of reflectivity (and hence ischemia) in the retina without any invasive examination is reliable, repeatable, reproducible and feasible for clinical use. Registry: ClinicalTrials.gov, Protocol ID: EK 417,102,016, TRN: NCT03061526, Registration date: 19 February 2017.

Indexed as

RetinaRetinal Artery OcclusionRetinal Vein OcclusionTomography, Optical CoherenceAdultAgedFemaleHumansMaleMiddle AgedReproducibility of ResultsOCT imagesReflectivity changesRetinal artery occlusionRetinal ischemiaRetinal vein occlusion

Identifiers

PMID41044164
PMCPMC12494890

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.