Evidence map›Paper›PMID 41042900›Full record

ArticleAnalytical chemistry2025

Quantifying and Utilizing Electroosmotic Flow for Mechanical Measurements with the Scanning Ion Conductance Microscope.

Johannes Rheinlaender, Tilman E Schäffer

Abstract read
In one paragraph

Article in Analytical chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. A Correlative SICM-OPM Platform for Surface and Volumetric Imaging in Live Cells.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Johannes RheinlaenderInstitute of Applied Physics, University of Tübingen, Auf der Morgenstelle 10, 72076 Tübingen, Germany.ORCID 0000-0002-1976-9245
Tilman E SchäfferInstitute of Applied Physics, University of Tübingen, Auf der Morgenstelle 10, 72076 Tübingen, Germany.ORCID 0000-0001-5643-8384

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The scanning ion conductance microscope (SICM) is an emerging imaging technique for the investigation of delicate samples on the nanometer scale in liquid environments using ion current through a glass nanopipette. In recent years, the SICM has been increasingly applied to mechanical measurements, typically using a microfluidic flow in the nanopipette induced by hydrostatic pressure. Here, we introduce the use of electroosmotic flow (EOF) in mechanical SICM measurements. We show that the EOF in small SICM nanopipettes is comparable to the flow induced by commonly applied hydrostatic pressures. We quantify the electroosmotic mobility, which is a central parameter of EOF but strongly depends on experimental conditions, by measuring the streaming current independent of nanopipette geometry. Using decane microdroplets, we show that both EOF and hydrostatic pressure can be used to mechanically probe elastic samples on the nanometer scale. We then develop a numerical model to quantify the stiffness and the Young's modulus of elastic samples using EOF. Finally, we use EOF to map the Young's modulus of living cells, which gives similar results to the hydrostatic pressure method. We thereby demonstrate that EOF can be used to quantitatively probe sample stiffness with the SICM.

Identifiers

PMID41042900
PMCPMC12547853

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.