Evidence map›Paper›PMID 41040412›Full record

ArticleFrontiers in bioengineering and biotechnology2025

Biomechanically optimized 3D-Printed titanium prostheses with stiffener arrangement for critical femoral diaphyseal defects: early weight-bearing capacity and combat readiness validated through integrated biomechanical-FEA approach.

Guo-Sen Li, Hao Li, Da Liu, Rui Yi, Yi Cui, Hong-Da Lao, Xiao-Yang Nie, Min Zhao, Cheng-Fei Du, Yong-Qing Xu and 1 more

Erratum issuedAbstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

11 authors.

Guo-Sen LiDepartment of Orthopaedics, The 908th Hospital of Joint Logistic Support Force, Nanchang, Jiangxi, China.
Hao LiDepartment of Orthopaedics, The 908th Hospital of Joint Logistic Support Force, Nanchang, Jiangxi, China.
Da LiuThe General Hospital of Western Theater Command, Chengdu, Sichuan, China.
Rui YiThe Seventh Medical Center, Chinese PLA General Hospital, Beijing, China.
Yi CuiInstitute of Orthopedic Trauma, 920th Hospital of Chinese PLA Joint Logistics Support Force, Kunming, Yunnan, China.
Hong-Da LaoDepartment of Orthopaedics, The 908th Hospital of Joint Logistic Support Force, Nanchang, Jiangxi, China.
Xiao-Yang NieDepartment of Orthopaedics, The 908th Hospital of Joint Logistic Support Force, Nanchang, Jiangxi, China.
Min ZhaoDepartment of Orthopaedics, The People's Hospital of Yingtan City, Yingtan, Jiangxi, China.
Cheng-Fei DuTianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Technology, Tianjin, China.
Yong-Qing XuInstitute of Orthopedic Trauma, 920th Hospital of Chinese PLA Joint Logistics Support Force, Kunming, Yunnan, China.
Jiang-Jun ZhouDepartment of Orthopaedics, The 908th Hospital of Joint Logistic Support Force, Nanchang, Jiangxi, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Critical femoral diaphyseal defects exceeding 3 cm present significant challenges in trauma and military orthopedics, particularly in blast injury scenarios requiring rapid rehabilitation. Methods: The purpose of this experiment was to evaluate the biomechanical Results: Key findings demonstrate comparable compressive stiffness between prostheses groups (Group A: 764.12±112.63 N/mm; Group B: 693.63±136.31 N/mm) and intact femurs (808.59±18.1 N/mm, p>0.05). The torsional stiffness is comparable between prostheses groups (Group A: 2.28±0.15 Nm/°; Group B: 2.18±0.22 Nm/°) versus diaphyseal fractures without defects (2.01±0.19 Nm/°). The stiffness results comply with mobilization requirements. FEA revealed maximum von Mises stresses in prosthesis fixation systems below the yield strength of Ti6Al4V, with digital image correlation validating the stress distribution patterns. The porous scaffold design achieved optimal modulus (1,132.85 MPa) between cortical and cancellous bone, reducing the "stress shielding" effect. Both prostheses endured 1800 N cyclic loading (100,000 cycles ≈, 13.3 years of physiological use) without structural failure. Discussion: These customized prostheses address critical military medical needs by enabling immediate weight-bearing, reducing surgical complexity compared to bone transport techniques, and maintaining long-term mechanical integrity. The stiffener design philosophy and additive manufacturing flexibility provide adaptable solutions for complex combat-related trauma, significantly advancing early functional recovery in resource-constrained environments.

Indexed as

3D-printed prosthesisbiomechanical compatibilitycritical bone defectfinite element analysismilitary traumastiffenertitanium alloy

Identifiers

PMID41040412
PMCPMC12484202

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.