Evidence map›Paper›PMID 41039127›Full record

ArticleMikrochimica acta2025

A novel tripod probe and lateral flow test to improve CRISPR/Cas12a assay: benefits of branched probe based on trebler phosphoramidite modification.

Irina V Safenkova, Maria V Kamionskaya, Aleksandr V Ivanov, Anatoly V Zherdev, Boris B Dzantiev

Abstract read
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Irina V SafenkovaA.N. Bach Institute of Biochemistry, Research Centre of Biotechnology of the Russian Academy of Science, Moscow, Russian Federation.ORCID 0000-0002-3621-4321
Maria V KamionskayaA.N. Bach Institute of Biochemistry, Research Centre of Biotechnology of the Russian Academy of Science, Moscow, Russian Federation.ORCID 0009-0004-7656-4360
Aleksandr V IvanovA.N. Bach Institute of Biochemistry, Research Centre of Biotechnology of the Russian Academy of Science, Moscow, Russian Federation.ORCID 0000-0002-0000-0401
Anatoly V ZherdevA.N. Bach Institute of Biochemistry, Research Centre of Biotechnology of the Russian Academy of Science, Moscow, Russian Federation.ORCID 0000-0003-3008-2839
Boris B DzantievA.N. Bach Institute of Biochemistry, Research Centre of Biotechnology of the Russian Academy of Science, Moscow, Russian Federation. dzantiev@inbi.ras.ru.ORCID 0000-0003-4008-4918

Funding

Russian Science Foundation 23-46-10011
6 · The paper itself

Abstract

CRISPR/Cas12a-based assays, when integrated with lateral flow tests (LFTs), provide highly specific nucleic acid detection in a simple, rapid, and equipment-free format. Nevertheless, traditional DNA probes utilized for cleavage by Cas12a have limitations as the cleaved probe only has one label. To overcome this challenge, we engineered a novel type of DNA probe with multiple fluorescein (FAM) labels and a biotin-labeled single-stranded DNA fragment (polyFAM probe). The cleaved polyFAM parts of the probes were detected using a specially designed sandwich LFT, where FAM-specific antibodies were immobilized in the test zone and conjugated with gold nanoparticles. The LFT ensured accurate recognition of the cleaved polyFAM fragments within 10 min. A comparison of five distinct polyFAM probes revealed that the highest signal-to-noise ratio was achieved with a tripod-branched probe synthesized via trebler phosphoramidite modification. Each arm of the tripod probe consists of a hexaethylene glycol spacer ending in a FAM label. Upon Cas12a cleavage, the tripod structure carrying three FAMs is released and detected by LFT. A rapid magnetic separation strategy was subsequently implemented, facilitating the efficient removal of uncleaved probes via biotin-streptavidin capture within 5 min. The CRISPR/Cas12a-tripod-LFT strategy demonstrated excellent sensitivity without preamplification, with a detection Limit of 1.4 pM for DNA target of Salmonella Typhimurium. The CRISPR/Cas12a-tripod-LFT with preliminary loop-mediated isothermal amplification enabled the detection of as few as 0.3 cells per reaction. This innovative tripod probe with corresponding LFT creates a universal, sensitive, rapid, and equipment-free biosensing platform for CRISPR/Cas12a-based diagnostics in point-of-care applications.

Indexed as

Bacterial ProteinsBiosensing TechniquesCRISPR-Associated ProteinsCRISPR-Cas SystemsDNA ProbesEndodeoxyribonucleasesOrganophosphorus CompoundsFluorescent DyesGoldLimit of DetectionMetal NanoparticlesBacterial ProteinsCas12a proteinCRISPR-Associated ProteinsDNA ProbesEndodeoxyribonucleasesFluorescent DyesGoldOrganophosphorus CompoundsphosphoramiditeCollateral cleavageCRISPR/Cas12aLateral flow stripMagnetic separationPoint-of-care testingSalmonellaTrans-target

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.