Evidence map›Paper›PMID 41036284›Full record

ArticleFrontiers in surgery2025

Surgical outcomes of the closure of mesenteric defects in side-to-side jejunoileal anastomosis plus proximal loop ligation (SSJIBL) using absorbable and non-absorbable surgical sutures.

Yonglin Li, Jing Wang, Chengyu Wu, Xiaojing Lu, Qi Zheng, Rongwei Wei, Ziliang Zong, Yigang Chen

Abstract read
In one paragraph

Article in Frontiers in surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yonglin Li *Department of General Surgery, Wuxi No. 2 Hospital, Jiangnan University Medical Center, Wuxi, China.
Jing Wang *Department of General Surgery, Wuxi No. 2 Hospital, Jiangnan University Medical Center, Wuxi, China.
Chengyu Wu *Department of General Surgery, The Affiliated Wuxi No. 2 Hospital of Nanjing Medical University, Wuxi, China.
Xiaojing LuDepartment of General Surgery, The Affiliated Wuxi No. 2 Hospital of Nanjing Medical University, Wuxi, China.
Qi ZhengDepartment of General Surgery, Wuxi No. 2 Hospital, Jiangnan University Medical Center, Wuxi, China.
Rongwei WeiDepartment of General Surgery, Wuxi No. 2 Hospital, Jiangnan University Medical Center, Wuxi, China.
Ziliang ZongDepartment of General Surgery, Wuxi No. 2 Hospital, Jiangnan University Medical Center, Wuxi, China.
Yigang ChenDepartment of General Surgery, Wuxi No. 2 Hospital, Jiangnan University Medical Center, Wuxi, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Mesenteric hiatal hernia represents a significant complication following gastrointestinal surgery, and the closure of mesenteric defects has been shown to mitigate the risk of such hernias. SSJIBL, a surgical technique that has gained prominence in recent years, is widely acknowledged for its efficacy in glucose reduction and its association with fewer complications. Nevertheless, there remains a gap in the literature regarding the optimal suture choice for closing mesenteric defects, as no definitive studies or reports have addressed this specific issue to date. So we wanted to know what sutures we could use to more safely close the mesenteric defect. Materials and methods: 36 New Zealand rabbits were divided into three groups, NC, Absorbable suture and Non-absorbable suture. Group NC was not operated, group Absorbable suture close the mesenteric defect with absorbable suture, and group Non-absorbable suture close the mesenteric defect with non-absorbable suture; the rabbits were weighed and measured monthly, and after three months, the rabbits were observed to see if there was any internal hernia and to detect the tethered lacunae tension. Results: According to the results of the experiment, both absorbable suture and non-absorbable suture can induce infiltration of inflammatory cells and enhance adhesion strength relative to the NC group. Conclusion: Both absorbable and non-absorbable sutures are safe and reliable.

Indexed as

absorbable suturemesenteric defectmesenteric hiatal hernianon-absorbable sutureSSJIBL

Identifiers

PMID41036284
PMCPMC12479435

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.