Evidence map›Paper›PMID 41034972›Full record

ArticleJournal of neuroengineering and rehabilitation2025

A time-efficient continuous ramp protocol for data-driven walking energy expenditure estimation across multiple speeds.

Jeong Hyunho, Park Sukyung

Abstract read
In one paragraph

Article in Journal of neuroengineering and rehabilitation, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Jeong HyunhoMechanical Engineering Department, KAIST, 291, Daehak-ro, 34141, Daejeon, Korea, Republic of.
Park SukyungMechanical Engineering Department, KAIST, 291, Daehak-ro, 34141, Daejeon, Korea, Republic of. sukyungp@kaist.ac.kr.

Funding

Korea Advanced Institute of Science and Technology N11240052the National Research Foundation of Korea RS-2024-00356657
6 · The paper itself

Abstract

backgroundRecent research has sought to use data-driven models to estimate walking energy expenditure across multiple speeds via wearable devices. Many studies employ a discrete step protocol-repeatedly walking at a constant speed for several minutes-because indirect calorimetry depends on time-delayed respiratory responses. However, this approach becomes time-inefficient when constructing sufficiently diverse datasets for deep learning, which requires large amounts of distinctive data. To address this issue, we integrated a data-driven approach with a previously proposed continuous protocol wherein walking speeds are gradually increased within a single trial. The purpose of this study is to compare the effectiveness of such a continuous dataset for energy expenditure estimation against a conventional discrete approach.

methodsFourteen subjects walked on a treadmill wearing four IMUs, while energy expenditure was measured using an indirect calorimetry. In the continuous ramp protocol, subjects walked for 10 mins at speeds linearly increasing from 1.0 to 1.75 m/s. The discrete step protocol involved five speeds within the same range, each maintained for 6 mins. In the continuous ramp protocol, energy expenditure was mapped to each speed after compensating for respiratory delay, whereas in the discrete step protocol, we used averaged breath-by-breath measurements of the final 3 minutes. We compared the kinematics, kinetics, and energy expenditure between the two protocols. Subsequently, 13 additional subjects were recruited to compare a commercial smartwatch with linear and deep learning models trained on datasets from each protocol.

resultsAfter compensating for respiratory delays, no differences in energy expenditure were observed between the two protocols, although kinematic differences appeared at speeds above 1.5 m/s. These differences did not impair estimation accuracy: deep learning models trained on the discrete and continuous datasets showed comparable performance (13.1% vs. 10.7% mean error, respectively), both significantly outperforming the smartwatch. Furthermore, when trained on the more diverse data from the continuous ramp protocol, a deep learning model achieved uniformly low error across a broad speed range with only a single IMU.

conclusionThe continuous ramp protocol can generate a valid walking motion-energy expenditure dataset in a time-efficient manner, improving model performance by providing richer data diversity. This approach is not limited to walking speed but can be applied to other continuously changing exercise intensities across various forms of locomotion, thus promoting efforts to replace indirect calorimetry, traditionally requires extensive laboratory experiments.

Indexed as

Energy MetabolismWalkingWalking SpeedAdultCalorimetry, IndirectDeep LearningExercise TestFemaleHumansMaleWearable Electronic DevicesYoung AdultDeep learningEnergy expenditureEstimationGaitProtocol

Identifiers

PMID41034972
PMCPMC12487484

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.