ArticleBMC musculoskeletal disorders2025
Is diamond-shaped screw fixation a viable alternative for Pauwels type III fractures? A biomechanical comparison of three constructs.
Article in BMC musculoskeletal disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
backgroundPauwels type III femoral neck fractures are characterized by steep, vertically oriented fracture lines and are biomechanically unstable due to high shear and varus forces. While sliding hip screws (SHS) and cannulated screw (CS) constructs are commonly used, no consensus exists regarding the optimal fixation method for these challenging fractures. The diamond-shaped (rhomboid) configuration, incorporating four cannulated screws placed in both superior-inferior and anterior-posterior axes, has been proposed as a potential alternative, but remains insufficiently studied.
methodsIn this biomechanical study, 24 synthetic femur models with standardized Pauwels type III osteotomies were randomly assigned to three fixation groups (n = 8): inverted triangle cannulated screws (ICS), SHS with an anti-rotational screw (SHS + AS), and diamond-shaped cannulated screws (DCS). All models underwent static, dynamic (cyclic), and failure load testing using an Instron biomechanical testing system. Displacement at the fracture site was evaluated using a digital image correlation (DIC) method.
resultsThe DCS group demonstrated the highest mean failure load and superior stiffness in both static and post-cyclic testing. Additionally, shear displacement was significantly lower in the DCS group during static loading compared to the SHS + AS group (p < 0.05). No significant differences were found between ICS and SHS + AS groups in most parameters.
conclusionThe diamond-shaped cannulated screw configuration exhibited promising biomechanical performance in Pauwels type III fractures, offering enhanced resistance to shear forces. Considering the minimally invasive nature of CS fixation, this configuration may serve as a viable alternative to conventional methods. Further studies are needed to validate these findings in cadaveric and clinical settings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials