Evidence map›Paper›PMID 41034279›Full record

ArticleScientific reports2025

Clinical trials of GPE-based muscle support algorithm for robotic hip exoskeleton: a pilot study.

Dongbin Shin, Yonghyun Lee, Younghoon Ji, Hyeyoun Jang, Changsoo Han, Yeonjoon Lee, Changwon Moon, Donghwee Kim, Mijung Kim

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Dongbin Shin *Hexar Humancare, R&D Center and S/W Development Team, Ansan, 15588, South Korea. dbshin@hexarsys.com.
Yonghyun Lee *Department of Artificial Intelligence, Major in Bio Artificial Intelligence, Hanyang University, Ansan, 15588, South Korea.
Younghoon JiHexar Humancare, R&D Center and S/W Development Team, Ansan, 15588, South Korea.
Hyeyoun JangHexar Humancare, R&D Center and S/W Development Team, Ansan, 15588, South Korea.
Changsoo HanHexar Humancare, R&D Center and S/W Development Team, Ansan, 15588, South Korea.
Yeonjoon LeeDepartment of Computer Science, Hanyang University, Ansan, 15588, South Korea.
Changwon MoonDepartment of Rehabilitation Medicine, Chungnam National University College of Medicine, Daejeon, 35015, South Korea.
Donghwee KimDepartment of Physical Medicine and Rehabilitation, Korea University College of Medicine, Ansan, 15459, South Korea.
Mijung KimDepartment of Rehabilitation Medicine, Hanyang University College of Medicine, Seoul, 04763, South Korea.

Funding

the Korea Medical Device Development Fund grant funded by the Korea government (the Ministry of Science and ICT, the Ministry of Trade, Industry and Energy, the Ministry of Health & Welfare, Republic of Korea, the Ministry of Food and Drug Safety) (Project Number: 202013B01)
6 · The paper itself

Abstract

With the advent of an aging society, the lack of physical activity has become a major concern, leading to various age-related diseases. To prevent such issues, research on wearable robots aimed at improving gait has been actively pursued. Among them, exoskeleton robots, a widely used approach, require an accurate understanding of the user's gait cycle for effective control. Various studies have explored gait cycle detection and prediction methods depending on the type of gait robot platform and the use of sensors. However, a major challenge in gait cycle prediction algorithms remains the issue of nonlinear predictive trajectories. In the study, a robotic hip exoskeleton (RHE) was utilized to implement an enhanced gait phase estimation (GPE) algorithm integrated with a muscle support system. Participants were divided into two groups (Group A and Group B) based on their initial gait performance, and the effectiveness of gait rehabilitation training was evaluated. The results showed that in the 10-meter walk test (10MWT), walking time decreased by approximately 5% in Group A and 27% in Group B. In the 6-minute walk test (6MinWT), walking distance increased by approximately 1% in Group A and 14% in Group B. Group B, which had lower initial gait performance, showed a greater gait performance improvement rate compared to Group A, which had higher initial gait performance. Through the gait performance results of the two groups, the applicability of the GPE based muscle support algorithm was confirmed.

Indexed as

AlgorithmsExoskeleton DeviceGaitHipMuscle, SkeletalRoboticsAdultFemaleHumansMaleMiddle AgedPilot ProjectsWalking

Identifiers

PMID41034279
PMCPMC12489056

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.