Evidence map›Paper›PMID 41032615›Full record

ArticleScience advances2025

A wireless, implantable sensor for continuous monitoring of blood leakage after endovascular aneurysm repair.

Sun Young Park, Soo Hyun Kim, Unseong Baik, Seung Jae Huh, Raudel Avila, Hyeon Ho Shin, Hyoungsuk Yoo, Heungsoo Shin, Jin-Tae Kim, Young-Hyo Lim and 1 more

Abstract read
In one paragraph

Article in Science advances, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Advances in Cellulose-Based Materials for Bionic Sensors.Macromolecular rapid communications · 2026
    Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Sun Young ParkDepartment of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea.ORCID 0009-0009-8206-0704
Soo Hyun KimDepartment of Artificial Intelligence Semiconductor Engineering, Hanyang University, Seoul 04763, Republic of Korea.ORCID 0009-0007-7932-0793
Unseong BaikDepartment of Mechanical Engineering, POSTECH, Pohang 37673, Republic of Korea.ORCID 0009-0005-9450-8132
Seung Jae HuhDepartment of Bioengineering, Hanyang University, Seoul 04763, Republic of Korea.
Raudel AvilaDepartment of Mechanical Engineering, Rice University, Houston, TX 77005, USA.ORCID 0009-0005-0092-5307
Hyeon Ho ShinDepartment of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea.ORCID 0000-0003-2502-2807
Hyoungsuk YooDepartment of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea.
Heungsoo ShinDepartment of Bioengineering, Hanyang University, Seoul 04763, Republic of Korea.ORCID 0000-0002-9036-155X
Jin-Tae KimDepartment of Mechanical Engineering, POSTECH, Pohang 37673, Republic of Korea.ORCID 0000-0001-9933-1931
Young-Hyo LimDivision of Cardiology, Department of Internal Medicine, College of Medicine, Hanyang University, Seoul 04763, Republic of Korea.ORCID 0000-0001-7203-7425
Yei Hwan JungDepartment of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea.ORCID 0000-0002-1754-2602

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Endovascular aneurysm repair, a treatment for abdominal aortic aneurysms, carries the risk of recurrence due to endoleaks following stent graft implantation. Since these leaks do not present with specific symptoms, regular follow-up is necessary; however, now, only imaging-based monitoring is available. This study proposes an ultrathin flexible sensor inserted endovascularly with a stent to detect type I endoleaks, which pose the highest rupture risk. A coplanar capacitive sensor was attached to the stent graft using a specially developed flexible thermal adhesive to monitor blood leakage, without compromising the stent graft's function. It seamlessly folds and unfolds with the stent, allowing implantation through catheter-based procedures. Experimental validation confirmed that the sensor does not induce blood leakage and demonstrated long-term stability and functionality under vascular and dynamic conditions. This technology enables wireless monitoring of endoleak status, facilitates timely intervention, and improves postoperative outcomes by reducing the risk of recurrent aneurysms.

Indexed as

Aortic Aneurysm, AbdominalBlood Vessel Prosthesis ImplantationEndoleakEndovascular ProceduresWireless TechnologyAnimalsEndovascular Aneurysm RepairHumansMonitoring, PhysiologicStents

Identifiers

PMID41032615
PMCPMC12487876

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.