Evidence map›Paper›PMID 41032498›Full record

ArticlePloS one2025

Methodological issues in visible LED therapy dermatological research and reporting.

David Robert Grimes

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Spectral emission variability in commercial led masks for cosmetic use.Photochemical & photobiological sciences : Official journal of the European Photochemistry Association and the European Society for Photobiology · 2026
    Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

David Robert GrimesTCD Biostatistics Unit, Discipline of Public Health and Primary Care, School of Medicine, Trinity College Dublin, Dublin, Ireland.ORCID 0000-0003-3140-3278

Funding

Wellcome Trust 214461/A/18/Z
6 · The paper itself

Abstract

backgroundThe advent of mass-market Light Emitting Diodes (LEDs) has seen considerable interest in potential dermatological applications of LED light photobiomodulation (PBM) for a range of conditions, with a thriving market for direct-to-consumer LED treatments, including red light, blue light, and yellow light wavelengths. Evidence of efficacy is however mixed, and studies report a wide range of irradiances and wavelengths as well as outcome measures, rendering interpretation, comparison, and even efficacy evaluation prohibitive and impeding evidence synthesis.

methodsThis work establishes a model for comparing patient received doses, applying this to existent studies to ascertain potential inhomogeneity in reported doses and wavelengths employed. Patient doses were contrasted to equivalent solar exposure time needed to achieve fluences reported at specified wavelengths in the red light (RL), blue light (BL), and yellow light (YL) portion of the spectrum, yielding a comparison of reported doses to typical solar irradiance at the Earth's surface. Methodological aspects including dose validation, blinding, and bias were also analysed.

results27 relevant studies for dermatological conditions including acne vulgaris ([Formula: see text], 33.3%), wrinkle-reduction ([Formula: see text]18.5%), wound-healing ([Formula: see text], 11.1%), psoriasis severity ([Formula: see text], 11.1%), and erythemal index ([Formula: see text], 25.9%) were assessed. Outcome measures were highly heterogeneous between studies, with total patients ranging from 14 - 105 (median: 26). Fluences and wavelengths used in treatment differed over three orders of magnitude across studies even for the same conditions ([Formula: see text], median: [Formula: see text]. Derived equivalent solar time ranged from 0.01-19.35 hours (median: 3.3 hours), with central wavelengths between 405nm (BL) - 660nm (RL). No studies reported any dose validation, 10 (37.0%) were sponsored by the device manufacturer with a further 3 (11.1%) conducted by commercial dermatology practices offering the therapy under investigation. Assessors were unblinded to the treatment/ control groups in 33.3% ([Formula: see text]), while a further 9 (33.3%) did not have any non-light control group, leaving only 33.3% ([Formula: see text] with both control group and blinded outcome assessment.

conclusionsResults of this analysis suggest that fluences, wavelengths, and effective dose vary inconsistently between studies with often scant biological justification. This analysis suggests that better dose quantification and understanding of the underlying biophysics as well as plausible biological justifications for various wavelengths and fluences are imperative if LED therapy studies for dermatology are to be informative and research replicability improved.

Indexed as

DermatologyPhototherapySkin DiseasesHumansLight

Identifiers

PMID41032498
PMCPMC12488025

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked