Evidence map›Paper›PMID 41032172›Full record

ArticleEuropean radiology2026

Intelligent extraction of CT image landmarks for improving cam-type femoroacetabular impingement assessment.

Sareh Tayyebinezhad, Mansoor Fatehi, Hossein Arabalibeik, Hossein Ghadiri

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Sareh TayyebinezhadDepartment of Medical Physics and Biomedical Engineering, Tehran University of Medical Science, Tehran, Iran.
Mansoor FatehiSohrevardi Imaging Center, Tehran, Iran.
Hossein ArabalibeikResearch Center for Biomedical Technologies and Robotics (RCBTR), Tehran University of Medical Sciences, Tehran, Iran.
Hossein GhadiriDepartment of Medical Physics and Biomedical Engineering, Tehran University of Medical Science, Tehran, Iran. h-ghadiri@tums.ac.ir.ORCID http://orcid.org/0000-0001-7903-6273

Funding

Tehran University of Medical Sciences and Health Services 99-3-373-49298
6 · The paper itself

Abstract

objectivesFemoroacetabular impingement (FAI) with cam-type morphology is a common hip disorder that can result in groin pain and eventually osteoarthritis. The pre-operative assessment is based on parameters obtained from x-ray or computed tomography (CT) scans, namely alpha angle (AA) and femoral head-neck offset (FHNO). The goal of our study was to develop a computer-aided detection (CAD) system to automatically select the hip region and measure diagnostic parameters from CT scans to overcome the limitations of the tedious and time-consuming process of subjectively selecting CT image slices to obtain parameters. MATERIALS AND

methods271 cases of ordinary abdominopelvic CT examination were collected retrospectively from two hospitals between 2018 and 2022, each equipped with a distinct CT scanner. First, a convolution neural network (CNN) was designed to select hip region slices among abdominopelvic CT scan image series. This CNN was trained using 80 CT scans divided into 50%, 20%, and 30% for training, validation and testing groups, respectively. Second, the most appropriate oblique slice passing through the femoral head-neck complex was selected, and AA and FHNO landmarks were calculated using image-processing algorithms. The best oblique slices were selected/measured manually for each hip as ground truth and its related parameters.

resultsCT hip-region selection using CNN yielded 99.34% accuracy. Pearson correlation coefficient between manual and automatic parameters measurement were 0.964 and 0.856 for AA and FHNO, respectively.

conclusionThe results of this study are promising for future development of a CAD software application for screening CT scans that may aid physicians to assess FAI. KEY POINTS: Question Femoroacetabular impingement is a common, underdiagnosed hip disorder requiring time-consuming image-based measurements. Can AI improve the efficiency and consistency of its radiologic assessment? Findings Automated slice selection and landmark detection using a hybrid AI method improved measurement efficiency and accuracy, with minimal bias confirmed through Bland-Altman analysis. Clinical relevance An AI-based method enables faster, more consistent evaluation of cam-type femoroacetabular impingement in routine CT images, supporting earlier identification and reducing dependency on operator experience in clinical workflows.

Indexed as

Anatomic LandmarksFemoracetabular ImpingementRadiographic Image Interpretation, Computer-AssistedTomography, X-Ray ComputedAdultAlgorithmsFemaleHumansMaleMiddle AgedNeural Networks, ComputerRetrospective StudiesYoung AdultComputed tomographyFemoroacetabular impingementHipMusculoskeletal artificial intelligence

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.