Evidence map›Paper›PMID 41031820›Full record

ArticleJournal of orthopaedic research : official publication of the Orthopaedic Research Society2025

Membrane Filtration of Sonication Fluid-A Promising Adjunctive Method for the Diagnosis of Low-Grade Infection in Presumed Aseptic Nonunion.

Katharina Trenkwalder, Sandra Erichsen, Ferdinand Weisemann, Peter Augat, SAND Research Group, Simon Hackl

Abstract readMulticenter Study
In one paragraph

Article in Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Katharina TrenkwalderInstitute for Biomechanics, BG Unfallklinik Murnau, Murnau am Staffelsee, Germany.ORCID 0000-0001-5989-0755
Sandra ErichsenInstitute for Biomechanics, BG Unfallklinik Murnau, Murnau am Staffelsee, Germany.
Ferdinand WeisemannDepartment of Trauma Surgery, BG Unfallklinik Murnau, Murnau am Staffelsee, Germany.
Peter AugatInstitute for Biomechanics, BG Unfallklinik Murnau, Murnau am Staffelsee, Germany.
SAND Research Group
Simon HacklInstitute for Biomechanics, Paracelsus Medical University, Salzburg, Austria.

Funding

This study was funded by the German Social Accident Insurance (DGUV, FF-FR 0276).
6 · The paper itself

Abstract

Treatment guidelines for fracture nonunion differ based on the presence or absence of infection. Low-grade infections without preoperative clinical signs of infection are difficult to distinguish from aseptic cases. Membrane filtration of sonication fluid (MF) has been shown to be a useful method for identifying septic nonunion. Therefore, the aim of this study was to evaluate the diagnostic value of MF in differentiating low-grade infected nonunion from aseptic cases. A prospective multicenter clinical study enrolled 75 patients with femoral or tibial shaft nonunion with planned revision surgery and without clinical suspicion of infection. During revision surgery, tissue from the nonunion zone was sampled for culture and histopathology, and the implant for sonication with MF and colony forming unit (CFU) quantification. Infection was diagnosed according to the diagnostic criteria for fracture-related infection. The diagnostic performance of MF CFU count was evaluated by receiver operating characteristic (ROC) curve and compared with that of tissue culture (TC), sonication fluid broth culture (SFC), and Histopathological Osteomyelitis Evaluation Score (HOES). Fifty-three nonunion cases were aseptic, and 22 had a low-grade infection. ROC curve had an area under the curve of 0.84. The optimal CFU cutoff to discriminate between low-grade infected and aseptic nonunion was 11.1 CFU/10 mL sonication fluid with 64% sensitivity and 89% specificity. SFC showed a higher sensitivity of 82% but a lower specificity of 81%. The sensitivity and specificity of TC were 77% and 96%, respectively, and those of HOES were 9% and 87%, respectively. Implementation of MF in clinical diagnostics as an adjunct to TC may improve the differential diagnosis between low-grade infected nonunion and aseptic nonunion.

Indexed as

Fractures, UnunitedSonicationAdolescentAdultAgedFemaleFemoral FracturesFiltrationHumansMaleMiddle AgedProspective StudiesTibial FracturesYoung Adultfracture‐related infectionimplant sonicationlow‐grade infected nonunionmembrane filtrationsuspected aseptic nonunion

Identifiers

PMID41031820
PMCPMC12066970

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.