Evidence map›Paper›PMID 41030820›Full record

ArticleJournal of experimental orthopaedics2025

A novel handheld wireless robot for total knee arthroplasty: Early experiences and clinical results.

Alexander P Sah, James L Womack, Yair D Kissin, Eytan M Debbi, Trevor R Cotter

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Observational
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Alexander P SahWashington Hospital Healthcare System Fremont California USA.ORCID https://orcid.org/0000-0002-0555-2395
James L WomackGolden Valley Memorial Healthcare Clinton Missouri USA.ORCID https://orcid.org/0000-0003-3068-7045
Yair D KissinHackensack University Medical Center Hackensack New Jersey USA.ORCID https://orcid.org/0000-0002-0972-9717
Eytan M DebbiHospital for Special Surgery New York New York USA.ORCID https://orcid.org/0000-0001-7867-1400
Trevor R CotterTHINK Surgical, Inc. Fremont California USA.ORCID https://orcid.org/0000-0001-5868-3957

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The percentage of total knee arthroplasty (TKA) performed robotically (rTKA) is rising exponentially. While this technique has well-established accuracy improvements, there are mixed patient-reported outcome measure (PROM) benefits compared to manual TKA (mTKA). Potential challenges in workflow, restricted implant compatibility to the robot and system cost have limited robotic adoption. A new robot seeks to address these and other rTKA concerns. Methods: This was a single surgeon retrospective series of the first 25 rTKA cases performed with a novel, wireless, handheld, open-implant robot and 25 mTKA cases. Data were recorded to observe performance and safety outcomes, including X-ray-based hip-knee-ankle (HKA) angle measurements, adverse events (AEs), range of motion (ROM), and PROMs including pain and knee society score (KSS). Case times for a subset of cases were recorded. rTKA cases were completed with implants not previously used by the surgeon. mTKA cases used implants and instrumentation standard to the surgeon's practice. Patients were tracked up to 3 months. Results: rTKA and mTKA cases both yielded positive clinical results. There were 0/25 HKA angle outliers (>3° from plan) and 1/25 outliers in the rTKA and mTKA cohorts, respectively. No AEs were observed in either group at follow-up. rTKA case times were similar to mTKA by case 5, with rTKA setup under 8 min for most cases. There were no differences in ROM or PROMs between cohorts. Conclusion: rTKA preliminarily showed safe and effective outcomes in early results. Surgeon and staff adoption showed minimal hurdles at this institution, as rTKA case with an implant system new to the surgeon were similar within five cases to mTKA case times using an implant system known to the surgeon, with comparable clinical results. This initial experience suggests the system may offer a more accessible alternative to existing robotic options, though further study is needed. Level of Evidence: Level IV.

Indexed as

clinical outcomeskneeorthopaedicsrobotic surgerytotal knee arthroplasty

Identifiers

PMID41030820
PMCPMC12477546

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.