Calibration of multisite raters for prospective visual reads of amyloid PET scans.
Article in Alzheimer's & dementia : the journal of the Alzheimer's Association, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Impact of adjunctive quantitative analysis on visual interpretation of amyloid PET: a multiple tracer, multicentre study.European radiology · 2026Article
- Calibration of multisite raters for prospective visual reads of amyloid PET scans.Alzheimer's & dementia : the journal of the Alzheimer's Association · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
25 authors.
Funding
Abstract
introductionIn multicenter Alzheimer's disease studies, amyloid positron emission tomography (PET) visual reads are typically performed centrally by a few experts. Incorporating a broader reader network enhances scalability and generalizability.
methodsTen neuroimaging experts from eight Alzheimer's Disease Research Centers (ADRCs) visually read 180 amyloid PET scans (30 scans and 15 duplicate scans for each of four tracers, imaged across a wide variety of scanners), using preferred reading software without anatomical imaging or quantitation. Scans were classified as elevated or non-elevated per tracer-specific criteria. Inter- and intra-rater agreement was assessed.
resultsInter-rater agreement was substantial (Fleiss' κ = 0.78), with full consensus on 69% of scans. Inter-rater reliability was substantial to perfect across tracers (Fleiss' κ = 0.70-0.87). Intra-rater agreement was substantial to perfect (Cohen's κ = 0.79-1). Scans with intermediate (10-40 Centiloid) quantitation had lower reader agreement. DISCUSSION: A multicenter expert network achieved substantial agreement classifying amyloid PET scans. These scans provide a standard for reader training and reliability assurance in future studies. HIGHLIGHTS: Calibration methods ensure reliable amyloid positron emission tomography (PET) visual reads across multiple raters. Substantial agreement is possible across readers using their preferred tools. Agreement is also substantial regardless of the amyloid PET tracer used. Scans with intermediate (10-40 Centiloid) quantitation have lower reader agreement. The calibration set will become a training tool for amyloid PET visual read studies.