Evidence map›Paper›PMID 41028797›Full record

ArticleScientific reports2025

Simulation and analysis of magnetic fields around High-Voltage power lines using Python for enhanced safety and design insights.

Pius Erheyovwe Bubu, Val Hyginus Udoka Eze, Awafung Emmanuel Adie, Mundu Muhamad Mustafa, Kelechi John Ukagwu, Lasisi Kamoru Alamu

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Pius Erheyovwe BubuDepartment of Biomedical Engineering, School of Engineering and Applied Sciences, Kampala International University, Western Campus, Ishaka, Bushenyi, Uganda.
Val Hyginus Udoka EzeDepartment of Electrical, Telecommunication & Computer Engineering, School of Engineering and Applied Sciences, Kampala International University, Western Campus, Ishaka-Bushenyi, Uganda. udoka.eze@kiu.ac.ug.ORCID http://orcid.org/0000-0002-6764-1721
Awafung Emmanuel AdieDepartment of Biomedical Engineering, School of Engineering and Applied Sciences, Kampala International University, Western Campus, Ishaka, Bushenyi, Uganda.
Mundu Muhamad MustafaDepartment of Electrical, Telecommunication & Computer Engineering, School of Engineering and Applied Sciences, Kampala International University, Western Campus, Ishaka-Bushenyi, Uganda.
Kelechi John UkagwuDepartment of Electrical, Telecommunication & Computer Engineering, School of Engineering and Applied Sciences, Kampala International University, Western Campus, Ishaka-Bushenyi, Uganda.
Lasisi Kamoru AlamuDepartment of Electrical, Telecommunication & Computer Engineering, School of Engineering and Applied Sciences, Kampala International University, Western Campus, Ishaka-Bushenyi, Uganda.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate modeling of magnetic fields around high-voltage power lines is essential for public health protection, electromagnetic compatibility (EMC) planning, and infrastructure safety. This study presents a novel, open-source, Python-based simulation framework that rigorously computes magnetic flux density using the Biot-Savart Law, enhanced with ground-air boundary conditions via a modified finite element module. Simulations were conducted for three typical conductor configurations, horizontal, vertical, and triangular (delta) under balanced three-phase loading (132 kV, 100 A per phase), using Aluminium Conductor Steel-Reinforced (ACSR) 'Linnet' conductors mounted 10 m above ground level. The horizontal configuration exhibited the highest peak magnetic flux density, reaching 120 µT directly beneath the conductors and 104.2 µT at 1.5 m height, exceeding the ICNIRP (2020) public exposure limit of 100 µT. In contrast, the triangular layout produced the most uniform field distribution, with a peak of 57.6 µT and a standard deviation of 7.3 µT across the 0-2 m human exposure zone. The vertical arrangement, while exhibiting lower peak intensity, influenced a broader lateral dispersion, indicating potential implications for densely populated environments. Incorporation of ground-air interactions resulted in a 28.3% increase in local field intensity at 1.5 m due to constructive interference, necessitating up to 1.2 m reduction in safety clearance in worst-case exposure scenarios. Field measurements using a precision three-axis gaussmeter (± 0.01 µT) at 5 m, 10 m, and 15 m from the transmission line showed a maximum relative deviation of 0.74%, with absolute error ranging from 6.78 × 10⁻²¹ T to 1.53 × 10⁻⁷ T, validating the model's predictive fidelity. Incorporating boundary effects reduced spatial prediction error by 15-25% compared to boundary-excluded models. The simulation framework, developed using NumPy, SciPy, and Matplotlib, provides a cost-effective, scalable, and regulator-aligned tool for optimizing conductor layouts, mitigating electromagnetic exposure risks, and supporting compliance in transmission routing and urban planning. Future work will integrate conductor non-idealities, dynamic environmental loading, and transient power flow conditions to enhance applicability in smart grid and real-time EMF monitoring scenarios.

Indexed as

Electromagnetic modellingHigh-Voltage power linesMagnetic fieldsPublic health safetyPython simulation

Identifiers

PMID41028797
PMCPMC12485033

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked