Evidence map›Paper›PMID 41028564›Full record

ArticleJournal of imaging informatics in medicine2026

Deep Learning-Based Cardiac CT Coronary Motion Correction Method with Temporal Weight Adjustment: Clinical Data Evaluation.

Dan Yao, Chengxi Yan, Wang Du, Jingchao Zhang, Zhenzhen Wang, Sha Zhang, Minglei Yang, Shuangfeng Dai

Abstract read
In one paragraph

Article in Journal of imaging informatics in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Dan Yao *Department of Research Institute, Beijing Wandong Medical Technology Ltd., Beijing, 100016, China.ORCID http://orcid.org/0009-0004-6353-7945
Chengxi Yan *Department of Radiology, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710004, China.
Wang DuDepartment of Research Institute, Beijing Wandong Medical Technology Ltd., Beijing, 100016, China.
Jingchao ZhangDepartment of Research Institute, Beijing Wandong Medical Technology Ltd., Beijing, 100016, China.
Zhenzhen WangDepartment of Research Institute, Beijing Wandong Medical Technology Ltd., Beijing, 100016, China.
Sha ZhangDepartment of Research Institute, Beijing Wandong Medical Technology Ltd., Beijing, 100016, China.
Minglei YangDepartment of Research Institute, Beijing Wandong Medical Technology Ltd., Beijing, 100016, China. yangminglei122@163.com.ORCID http://orcid.org/0000-0002-6881-337X
Shuangfeng DaiDepartment of Research Institute, Beijing Wandong Medical Technology Ltd., Beijing, 100016, China. shfdai@163.com.ORCID http://orcid.org/0000-0003-0709-046X

Funding

Beijing Municipal Science and Technology Commission, Administrative Commission of Zhongguancun Science Park Z221100003522008National key Research and Development Program of China 2024YFC2417704
6 · The paper itself

Abstract

Cardiac motion artifacts frequently degrade the quality and interpretability of coronary computed tomography angiography (CCTA) images, making it difficult for radiologists to identify and evaluate the details of the coronary vessels accurately. In this paper, a deep learning-based approach for coronary artery motion compensation, namely a temporal-weighted motion correction network (TW-MoCoNet), was proposed. Firstly, the motion data required for TW-MoCoNet training were generated using a motion artifact simulation method based on the original no-artifact CCTA images. Secondly, TW-MoCoNet, consisting of a temporal weighting correction module and a differentiable spatial transformer module, was trained using these generated paired images. Finally, the proposed method was evaluated on 67 clinical data with objective metrics including peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), fold-overlap ratio (FOR), low-intensity region score (LIRS), and motion artifact score (MAS). Additionally, subjective image quality was evaluated using a 4-point Likert scale to assess visual improvements. The experimental results demonstrated a substantial improvement in both the objective and subjective evaluations of image quality after motion correction was applied. The proportion of the segments with moderate artifacts, scored 2 points, has a notable decrease of 80.2% (from 26.37 to 5.22%), and the proportion of artifact-free segments (scored 4 points) has reached 50.0%, which is of great clinical significance. In conclusion, the deep learning-based motion correction method proposed in this paper can effectively reduce motion artifacts, enhance image clarity, and improve clinical interpretability, thus effectively assisting doctors in accurately identifying and evaluating the details of coronary vessels.

Indexed as

Computed Tomography AngiographyCoronary AngiographyCoronary VesselsDeep LearningRadiographic Image Interpretation, Computer-AssistedAlgorithmsArtifactsHumansMotionCardiac CTAClinical data evaluationMotion correctionTemporal weight adjustment

Identifiers

PMID41028564
PMCPMC13230368

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.