ArticleJMIR formative research2025
The Validation and Accuracy of Wearable Heart Rate Trackers in Children With Heart Disease: Prospective Cohort Study.
Article in JMIR formative research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Using an Adult-Designed Wearable for Pediatric Monitoring: Practical Tutorial and Application in School-Aged Children With Obesity.Journal of medical Internet research · 2026Article
- Artificial intelligence in pediatric arrhythmias: current landscape, unique challenges, and translational perspectives.Frontiers in pediatrics · 2026Review
- Physiological load estimation in athletes using ECG-derived features and gradient-boosted modeling.Frontiers in public health · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Wearables are increasingly used in pediatric cardiology for heart rate (HR) monitoring due to advantages over traditional HR monitoring, such as prolonged monitoring time, increased patient comfort, and ease of use. However, their validation in this population is limited. Objective: The objective of this paper was to assess HR accuracy and validity from 2 wearables, the Corsano CardioWatch bracelet and the Hexoskin smart shirt, in children attending the pediatric cardiology outpatient clinic, exploring factors that influence accuracy, the Hexoskin shirt's arrhythmia detection efficacy, and patient satisfaction. Methods: Children with an indication for 24-hour Holter monitoring were equipped with a 24-hour Holter electrocardiogram (ECG; gold standard), together with both wearables. HR accuracy was defined as the percentage of HRs within 10% of Holter values, and agreement was assessed using Bland-Altman analysis. Subgroup analyses were conducted based on BMI, age, and time of wearing, among other factors. The association between accelerometry (expressed in gravitational units, g) and HR accuracy was analyzed to assess the impact of bodily movement on measurement accuracy. A blinded pediatric cardiologist analyzed Hexoskin shirt data for rhythm classification. Patient satisfaction was measured using a 5-point Likert scale questionnaire. Results: A total of 31 participants (mean age 13.2, SD 3.6 y; n=14, 45% female) and 36 participants (mean age 13.3, SD 3.9 y) were included for the CardioWatch and Hexoskin measurements, respectively. Mean accuracy was 84.8% (SD 8.7%) for the CardioWatch and 87.4% (SD 11%) for the Hexoskin shirt. Hexoskin shirt accuracy was notably higher in the first 12 hours (94.9%, SD 7.4%) compared to the latter 12 (80%, SD 16.7%; P<.001). Higher accuracy was observed at lower HRs (low vs high HR: CardioWatch: 90.9%, SD 9.3% vs 79%, SD 10.6%; P<.001 and Hexoskin shirt: 90.6%, SD 14% vs 84.5, SD 11.8%; P<.001). Both wearables demonstrated good agreement in their HR measurement with Holter readings (CardioWatch bias: -1.4 beats per minute [BPM]; 95% limits of agreement [LoA] -18.8 to 16.0. Hexoskin shirt bias: -1.1 BPM; 95% LoA -19.5 to 17.4). HR measurement accuracy declined during more intense bodily movements. Correct classification of the Hexoskin's shirt rhythm recordings was achieved in 86% (31/36) of cases. Patient satisfaction scores were significantly higher for both the CardioWatch (median 3.8, range 3.5-4.3; P<.001) and Hexoskin shirt (median 3.7, range 3.0-4.0; P<.001) compared to the Holter (median 2.6, range 2.1-3.2). Conclusions: The Corsano CardioWatch and Hexoskin shirt demonstrate good accuracy in pediatric HR monitoring and provide higher patient comfort than conventional monitoring. Both wearables show good agreement in relation to the gold standard device. However, measurement accuracy declines with increasing bodily movement and higher heart rates. More research is needed to explore the underlying causes for these inaccuracies and how to counteract them. The Hexoskin shirt also shows potential in arrhythmia detection. While further development is warranted, these wearables show promise in enhancing diagnostics, therapeutic monitoring, and patient safety in pediatric cardiology.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials