Evidence map›Paper›PMID 41026988›Full record

ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2025

Catheter tensile test: An in vitro evaluation for transradial access.

Daishiro Abe, Jun-Ichi Koyama, Yoshiki Hanaoka, Takuya Nakamura, Yu Nagai, Tetsuyoshi Horiuchi

Abstract read
In one paragraph

Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Daishiro AbeDepartment of Neurosurgery, Shinshu University School of Medicine, Matsumoto, Japan.ORCID 0000-0002-2824-8433
Jun-Ichi KoyamaDepartment of Neurosurgery, Shinshu University School of Medicine, Matsumoto, Japan.ORCID 0000-0003-4881-2457
Yoshiki HanaokaDepartment of Neurosurgery, Shinshu University School of Medicine, Matsumoto, Japan.ORCID 0000-0002-9288-1612
Takuya NakamuraDepartment of Neurosurgery, Shinshu University School of Medicine, Matsumoto, Japan.ORCID 0000-0003-0483-6561
Yu NagaiDepartment of Neurosurgery, Shinshu University School of Medicine, Matsumoto, Japan.ORCID 0009-0008-4461-9864
Tetsuyoshi HoriuchiDepartment of Neurosurgery, Shinshu University School of Medicine, Matsumoto, Japan.ORCID 0000-0001-5620-510X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

PurposeTransradial access (TRA) has been established for neurointervention; however, complications can occur at the radial access site. Radial artery spasm (RAS) is the most common complication of TRA. Under severe RAS conditions, pulling a catheter may occasionally result in radial artery injury and emergency surgery may be required. There have been no reports on the behavior of entrapped catheters/sheaths when pulled under severe RAS conditions. We conducted tensile tests on guide sheaths and balloon guide catheters to observe their damage in vitro and evaluate their potential to cause vascular injury.MethodsSix types of guide sheaths and balloon guide catheters were used in the test. The catheters were fixed to the testing machine and pulled. We observed how the catheter stretched and fractured. Additionally, a stress-strain curve was obtained from each examination to compare the characteristics of the catheters.ResultsCatheters were damaged in various ways. Some catheters were simply lengthened, whereas others were partially or completely torn. In the evaluation of the stress-strain curves, the slopes of the curves were almost equal among the catheters at the beginning of the test; that is, the hardness was almost the same for each catheter. As the strain increased, each exhibited different behavior.ConclusionCatheters can be damaged in various ways by stretching, which can cause vascular injuries. Neurointerventionists should be aware of possible catheter damage and vascular injury when catheters are entrapped.

Indexed as

Cathetersinterventional radiologyradial arteryvascular injuries

Identifiers

PMID41026988
PMCPMC12484055

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.