Evidence map›Paper›PMID 41026322›Full record

ArticleEJNMMI physics2025

Comparison of SZ-HRX and LEHR collimators for reduced-duration 123I-ioflupane brain SPECT/CT: a phantom study.

Mathieu Pavoine, Kouider-Othmane Kelatma, Clémence Robert, Alexandre Rintaud, Samuel Guigo, Thomas Godefroy, Pierre-Yves Salaün, Solène Querellou, David Bourhis

Abstract read
In one paragraph

Article in EJNMMI physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mathieu PavoineNuclear Medicine Department, University Hospital, Brest, France.
Kouider-Othmane KelatmaNuclear Medicine Department, University Hospital, Brest, France.
Clémence RobertNuclear Medicine Department, University Hospital, Brest, France.
Alexandre RintaudNuclear Medicine Department, University Hospital, Brest, France.
Samuel GuigoNuclear Medicine Department, University Hospital, Brest, France.
Thomas GodefroyNuclear Medicine Department, University Hospital, Brest, France.
Pierre-Yves SalaünNuclear Medicine Department, University Hospital, Brest, France.
Solène QuerellouNuclear Medicine Department, University Hospital, Brest, France.
David BourhisNuclear Medicine Department, University Hospital, Brest, France. david.bourhis@chu-brest.fr.ORCID http://orcid.org/0000-0001-8224-2027

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background

methodsA striatal phantom with 5 compartments (putamens, caudates, and background) was filled with different concentrations of

resultsSZ-HRX collimation had superior performance characteristics than LEHR, with relative changes in CNR, CV, and SBR of + 99%, -28% and + 42% respectively, without any decrease in spatial resolution or change in asymmetry index. SZ-HRX system seems to be at least as good as LEHR system, up to 40% of scan time reduction.

conclusionSZ-HRX collimation showed superior performance characteristics to LEHR collimation in the study of

Indexed as

123I-ioflupaneDatSCANLEHRParkinsonSingle photon emission computed tomographyStriatal phantomSZ-HRX

Identifiers

PMID41026322
PMCPMC12484530

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.