ArticleJournal of Yeungnam medical science2025
Experiences of healthcare providers and patients with diabetes mellitus regarding continuous glucose monitoring use in South Korea: a multicenter, cross-sectional survey study.
Article in Journal of Yeungnam medical science, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundDespite the increasing use of continuous glucose monitoring (CGM) systems, limited data exist on their perceived benefits and challenges among patients and healthcare providers. This study explored CGM-related experiences in South Korea.
methodsAn anonymous online survey was conducted between January and December 2021 at four university hospitals. Respondents included patients with diabetes mellitus (DM), physicians, and DM education nurses. The survey assessed the use of CGM, its benefits, and barriers. Most devices were first-generation CGMs: FreeStyle Libre 1 (Abbott Diabetes Care), Dexcom G6 (Dexcom Inc.), and Medtronic Guardian 3 (Medtronic MiniMed).
resultsAmong 1,010 patients (33.4% with type 1 DM [T1DM], 63.6% with type 2 DM [T2DM], and 3.1% others; mean age, 51.4±14.6 years), 92.7% found CGM helpful. Although 59.6% reported discomfort, 81.9% intended to continue using CGM, indicating that perceived benefits outweighed barriers. The key advantages were glucose monitoring without finger pricks (T1DM, 57.9%; T2DM, 56.2%) and maintenance of target glucose levels. Discomfort was related to discomfort during activities (53.8%), skin problems (45.0%), and pain (43.0%). Healthcare provider recommendations were associated with reduced discomfort (adjusted odds ratio, 0.36; 95% confidence interval, 0.21-0.60). Physicians (n=29) cited high costs as the main barrier (T1DM, 58.9%; T2DM, 64.8%); only 51.9% and 14.5% prescribed CGM for T1DM and T2DM, respectively. Insulin adjustment and glucose control were the main reasons for prescription, while cost (89.3%) and limited consultation time (67.9%) were barriers. DM educators (n=9) reported heavy workloads, with training and follow-up times averaging 31.7±7.5 minutes and 21.7±9.7 minutes, respectively; 77.8% of DM educators identified frequent patient inquiries as their greatest burden.
conclusionCGM provides significant clinical benefits but is limited by discomfort, costs, and educational burden. Sustained adoption requires device improvements, insurance support, and workforce expansion.