Evidence map›Paper›PMID 41024577›Full record

ArticleMagnetic resonance in medicine2026

Scalable spokes pTx pulses for 2D turbo-spin-echo imaging at 7 T.

Minghao Zhang, Christopher T Rodgers

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Minghao ZhangWolfson Brain Imaging Centre, University of Cambridge, Cambridge, United Kingdom.ORCID 0000-0002-5401-6070
Christopher T RodgersWolfson Brain Imaging Centre, University of Cambridge, Cambridge, United Kingdom.ORCID 0000-0003-1275-1197

Funding

Cambridge TrustMedical Research Council MR/M008983/1Medical Research Council N013433-1NIHR Cambridge Biomedical Research Centre BRC-1215-20014
6 · The paper itself

Abstract

purposeTurbo spin echo (TSE) is important clinically. Unfortunately, 7 T TSE suffers from B THEORY: We define scalable spokes pulses as having time-symmetric RF waveforms, antisymmetric in-plane gradients, and rephased subpulse slice-selection gradients. They produce flip angles that are approximately proportional to the applied voltage with voltage-independent phase patterns.

methodsScalable spokes pulses were designed for a phantom. Scaling behavior was characterized via Bloch simulations. Performance in terms of TSE echo homogeneity was assessed by extended phase graph simulations using in vivo field maps. Performance was validated for TSE acquisitions in a phantom and in vivo. Hippocampal TSE imaging was performed for four subjects comparing circularly polarized (CP), RF shimming, and scalable spokes pulses.

resultsScalable spokes pTx pulses show similar scaling behavior to previously proposed 3D k

conclusionScalable spokes pTx pulses produce flip angles that vary approximately linearly with peak voltage while maintaining consistent spatial patterns of phase. Together with their spatial flip-angle homogeneity, these pulses enable high-fidelity 2D slice-by-slice TSE imaging at 7 T, albeit with reduced slice coverage with our choice of homogeneity target under the current vendor-provided specific absorption rate constraints on 7 T MRI scanners.

Indexed as

Echo-Planar ImagingImage Processing, Computer-AssistedMagnetic Resonance ImagingAdultAlgorithmsBrainComputer SimulationHippocampusHumansPhantoms, Imagingfast spin echoparallel transmitscalable pulsesspokesturbo spin echo

Identifiers

PMID41024577
PMCPMC12681301

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.