Evidence map›Paper›PMID 41024213›Full record

Trial reportJournal of neuroengineering and rehabilitation2025

The clinical effects of the Össur Power Knee with phase-based and default control during sitting, standing, and walking.

T Kevin Best, C Andrew Seelhoff, Jeffrey Wensman, Robert D Gregg

Registry-linked trialAbstract readClinical Trial
In one paragraph

Trial report in Journal of neuroengineering and rehabilitation, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06138977 (Controlling Locomotion Over Continuously Varying Activities for Agile Powered Prosthetic Legs), which is not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06138977 narecruitingnot on this map

Controlling Locomotion Over Continuously Varying Activities for Agile Powered Prosthetic Legs

TypeinterventionalSponsorUniversity of MichiganRan2023 to 2028Enrolled40ConditionsAmputationArmsPowered prosthesis
3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Trial
  2. Effects of a Powered Knee-Ankle Prosthesis on Intact Joint Biomechanics Across Sustained Activities of Daily Life: A Case Series.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
    Article
  3. Controlling Powered Prosthesis Joint Impedance Over Continuous Stance Transitions Between Walking and Stair Ascent/Descent.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

T Kevin BestRobotics, University of Michigan, 2505 Hayward Street, Ann Arbor, MI, 48109, USA. tkbest@umich.edu.ORCID http://orcid.org/0000-0002-0404-2166
C Andrew SeelhoffMechanical Engineering, University of Michigan, 2505 Hayward Street, Ann Arbor, MI, 48109, USA.ORCID http://orcid.org/0009-0009-4012-030X
Jeffrey WensmanOrthotics and Prosthetics Center, Michigan Medicine, University of Michigan, 2850 S Industrial Hwy, Ann Arbor, MI, 48104, USA.ORCID http://orcid.org/0000-0002-9672-4518
Robert D GreggRobotics, University of Michigan, 2505 Hayward Street, Ann Arbor, MI, 48109, USA. rdgregg@umich.edu.ORCID http://orcid.org/0000-0002-0729-2857

Funding

Controlling Robot-Assisted Locomotion with Extended Kalman Filter Estimates of Phase and ActivityR01HD094772 · NICHD · UNIVERSITY OF TEXAS DALLAS · PI Robert D Gregg · 2018 to 2026
$4.3M
Eunice Kennedy Shriver National Institute of Child Health and Human Development R01HD094772National Science Foundation, United States DGE 1841052NICHD NIH HHS R01 HD094772
6 · The paper itself

Abstract

backgroundA lack of evidence of compelling clinical benefits is a key factor limiting the adoption of commercialized powered robotic knee prostheses into mainstream clinical practice. Previous studies have demonstrated mixed results, potentially due to a combination of limitations in prosthetic hardware, control algorithms, and testing methodologies.

methodsWe investigated the clinical effects of a commercialized robotic knee prosthesis (the latest generation Össur Power Knee

resultsThe clinical effects of the Power Knee varied with mobility level and the control policy used. The phase-based controller often produced stronger walking and sit/stand improvements for the higher mobility group compared to the default controller, though it also presented a steeper learning curve and reduced walk-to-sit transition speed. Conversely, the default control policy was perceived as easier to master but was less assistive to the higher mobility group and produced slower sit/stand cycles. Lower mobility participants experienced improvements in standing speed (HKIC: [Formula: see text]% faster, [Formula: see text]; ÖSSR: [Formula: see text]% faster, [Formula: see text]), inter-limb ground reaction force symmetry (HKIC: [Formula: see text], [Formula: see text]; ÖSSR: [Formula: see text], [Formula: see text]), and inter-limb peak knee moment symmetry (HKIC: [Formula: see text], [Formula: see text]; ÖSSR: [Formula: see text], [Formula: see text]) during sit-to-stand tasks relative to their passive prostheses. In contrast, higher mobility participants benefited less in sit/stand but showed improvements while walking including increased toe clearance (HKIC: [Formula: see text] mm, [Formula: see text]; ÖSSR: [Formula: see text] mm, [Formula: see text]), greater early stance knee flexion (HKIC: [Formula: see text], [Formula: see text]; ÖSSR: [Formula: see text], [Formula: see text]), and, for the HKIC policy, a reduced swing-phase peak hip flexion moment (HKIC: [Formula: see text] Nm/kg/(m/s), [Formula: see text]). Despite these biomechanical improvements and qualitative reports of reduced effort, neither control policy produced significant benefits in endurance or repeated task performance compared to the passive condition. Sit-to-stand cycle count in the lower mobility group was unchanged (HKIC: [Formula: see text], ÖSSR: [Formula: see text]), and it was reduced in the higher mobility group with the ÖSSR condition ([Formula: see text] fewer, [Formula: see text]). In the shuttle walk test, laps completed by higher mobility users decreased with HKIC ([Formula: see text] fewer, [Formula: see text]), and no significant differences were found for lower mobility users. No significant changes in fast walking distance or speed were observed across conditions.

conclusionsThe latest generation Power Knee can create clinical improvements in walking and sit/stand behaviors compared to passive (microprocessor) knees, though the effects are sensitive to the user's mobility level and the Power Knee's control policy. However, these improvements did not directly translate to improved functional performance or endurance. Some negative effects of the Power Knee were also observed including reduced agility, slower transitions, and thermal limitations, though some of these limitations could potentially be addressed through future control innovations or with more thorough acclimation. The observed benefits motivate future longitudinal studies to investigate the clinical effects of robotic knees compared to passive (microprocessor) knees in real-world settings and to elucidate how they could be best utilized in clinical practice.

trial registrationThe experimental protocol was approved by the University of Michigan Institutional Review Board (HUM00230065) on February 9th, 2024. The trial is registered with the National Institutes of Health under ClinicalTrials.gov ID NCT06138977.

Indexed as

Knee ProsthesisRoboticsSitting PositionStanding PositionWalkingAdultAgedAmputeesBiomechanical PhenomenaFemaleHumansMaleMiddle AgedProsthesis DesignProsthesis ControlRobotic ProsthesesTransfemoral Amputees

Identifiers

PMID41024213
PMCPMC12481835

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.