Evidence map›Paper›PMID 41024048›Full record

ArticleBMC oral health2025

Degree of conversion and microhardness of different composite resins polymerized with an advanced LED-curing unit.

Gozde Ozciftci, Hayal Boyacioglu, Lezize Sebnem Turkun

Abstract readComparative Study
In one paragraph

Article in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Gozde OzciftciDepartment of Restorative Dentistry, Ege University, School of Dentistry, Izmir, 35040, Turkey.
Hayal BoyaciogluDepartment of Statistics, Ege University, Faculty of Science, Izmir, 35040, Turkey.
Lezize Sebnem TurkunDepartment of Restorative Dentistry, Ege University, School of Dentistry, Izmir, 35040, Turkey. sebnemturkun@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe aim was to evaluate the effects of different curing times (3s/10s/20s) of an advanced Light-Emitting Diode (LED) curing unit on the degree of conversion (DC%), microhardness, and hardness ratio of three different composite resin materials.

methods180 cylindrical specimens (3 × 4 mm; n = 60) were prepared from PowerFill (Ivoclar, Liechtenstein), PowerFlow (Ivoclar), and Omnichroma Flow Bulk (Tokuyama, Japan). Half of the samples were used for the degree of conversion analysis (nDC = 30), and the other half for the microhardness test (n VHN = 30). All specimens were irradiated using a Light-Emitting Diode (LED) curing unit (Bluephase PowerCure, Ivoclar). Based on polymerization times: 3-second rapid, 10-second conventional, and 20-second conventional; three sub-groups were formed for each material (n = 10). The specimens' degree of conversion (DC%) was analyzed using Fourier Transform Infrared Spectroscopy (FTIR). Microhardness values were determined using the Vickers microhardness test, and the bottom-to-upper surface hardness ratios were calculated. The degree of conversion and microhardness were analyzed with a paired t-test, ANOVA, and Tukey tests (p < 0.05).

resultsComparisons among all groups revealed significant differences in upper and bottom DCs (p < 0.05). PowerFill exhibited higher values on both surfaces after 3s polymerization, while PowerFlow required 10s and Omnichroma Flow Bulk 20s to achieve similar results (p < 0.05). When the upper surface microhardness values were compared, no significant difference was found between PowerFlow and Omnichroma Flow Bulk in the 3s group (p = 0.623) and after 20s polymerization, between PowerFill and Omnichroma Flow Bulk (p = 0.082). Material type and polymerization duration significantly affected bottom surface microhardness values (p = 0.000). As the polymerization time increased, the bottom microhardness values of all materials increased. The highest microhardness ratio (HR) was obtained in the PowerFill group at 20 s (p = 0.029). In the PowerFlow group, no difference was found between HR values of 10s and 20s (p = 0.238). For Omnichroma Flow Bulk group, all polymerization durations showed significant differences (p = 0.000).

conclusionThe polymerization performed with an advanced LED curing unit in a shorter time (3s) resulted in varying polymerization efficiencies among different types of composite resins. For more homogeneous polymerization, it is advised to extend the duration to 10 s or longer.

Indexed as

Composite ResinsCuring Lights, DentalDental MaterialsLight-Curing of Dental AdhesivesHardnessHumansMaterials TestingPolymerizationSurface PropertiesTime FactorsComposite ResinsDental MaterialsBulk-fillComposite resinDegree of conversionLED curing unitMicrohardnessPolymerization

Identifiers

PMID41024048
PMCPMC12482808

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.