ArticleBMC oral health2025
Effects of inter-implant tooth loss and scan body material on digital impression accuracy: an in vitro study.
Article in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Article
- Digital impression accuracy of a novel scannable healing abutment: an in vitro study with three intraoral scanners.BMC oral health · 2026Article
- PEEK Intraoral Scan Bodies-A Scoping Review.Dentistry journal · 2026Review
- Materials and Techniques for Splinting Scan Bodies: A Scoping Review.Materials (Basel, Switzerland) · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
backgroundThe accuracy of digital implant scanning and the optimal choice of scanning bodies remain debated, particularly in cases involving multiple missing teeth between implants. This study aimed to investigate the influence of the number of missing teeth between implants on trueness, precision, and inter-implant distance deviation in digital implant impressions.
methodsThree maxillary models containing two implants and varying edentulous spans were fabricated: S1 (no missing teeth), S2 (one missing tooth), and S3 (two missing teeth). Titanium (Ti) and polyetheretherketone (PEEK) scanning bodies were used. Scanning was performed using both industrial and intraoral scanners. Data from the industrial scanners served as the control group, whereas data from the intraoral scanners constituted the experimental group. A three-dimensional deviation analysis using reverse engineering software (Geomagic Control X) quantified trueness, precision, and inter-implant distance deviation. A two-way analysis of variance (ANOVA) evaluated the effects of tooth loss, scanning body material, and their interaction on scanning accuracy.
resultsThe number of missing teeth considerably affected scanning accuracy. As tooth loss increased, mean trueness deteriorated in both Ti (S1: 0.18 ± 0.03 mm, S2: 0.35 ± 0.01 mm, S3: 0.56 ± 0.03 mm, p < 0.001) and PEEK (S1: 0.19 ± 0.15 mm, S2: 0.62 ± 0.11 mm, S3: 0.88 ± 0.08 mm, p < 0.001) groups. Moreover, precision worsened in both Ti (S1: 0.07 ± 0.02 mm, S2: 0.16 ± 0.04 mm, S3: 0.36 ± 0.17 mm, p < 0.001) and PEEK (S1: 0.11 ± 0.02 mm, S2: 0.28 ± 0.08 mm, S3: 0.77 ± 0.17 mm, p < 0.001) groups. Inter-implant distance deviations increased in Ti (S1: 0.28 ± 0.04 mm, S2: 0.32 ± 0.08 mm, S3: 0.37 ± 0.10 mm, p = 0.072) and PEEK (S1: 0.29 ± 0.11 mm, S2: 0.33 ± 0.03 mm, S3: 0.81 ± 0.11 mm, p < 0.001) groups. In the intergroup comparison between Ti and PEEK scanning bodies, significant differences were observed in the following parameters: Trueness: S2 (p < 0.001), S3 (p < 0.001); Precision: S1 (p < 0.001), S2 (p < 0.001), S3 (p < 0.001); Distance Deviation: S3 (p < 0.001).Two-way ANOVA showed a strong interaction between tooth loss and scanning body material.
conclusionsIncreased inter-implant tooth loss considerably reduced digital scanning accuracy. Ti scanning bodies provided superior spatial positioning accuracy compared with PEEK under the study conditions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials