Enhanced calibration method for wall-mounted RGSC cameras: Mitigating baseline drift caused by CT couch sagging.

Jiangtao Wang, Jinyou Hu, Xiangxiang Liu, Dashuang Luo, Yisong He, Lian Zou

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jiangtao WangCancer Center, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.ORCID 0009-0005-3659-3906
Jinyou HuCancer Center, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.
Xiangxiang LiuCancer Center, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.
Dashuang LuoCancer Center, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.
Yisong HeCancer Center, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.
Lian ZouCancer Center, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe drift signal due to CT couch sagging introduces intrinsic noise into respiratory signals, impairing the accuracy of tumor motion management. The purpose of this work is to present an enhanced calibration method to reduce calibration uncertainty and mitigate baseline drift caused by table sagging for the wall-mounted Respiratory Gating for Scanner (RGSC) camera.

methodsA weight of approximately 70 kg, simulating a patient's weight, was distributed on the CT table. The external ceiling laser light was adjusted laterally by ±10 cm to align three reflector blocks sequentially with the laser at predefined positions, ensuring accurate placement of the blocks at their corresponding positions. The blocks were then moved to the internal laser plane using the CT console. Subsequently, calibration measurements were performed at nine points at the combination of three lateral positions (the CT isocenter and ±10 cm laterally from the isocenter) and three longitudinal positions (the CT isocenter and ±15 cm longitudinally from the isocenter), by occluding the other two blocks and moving the couch longitudinally. For comparison, the Varian calibration method was also implemented.

resultsThe block positioning uncertainty was reduced from the millimeter level to the sub-millimeter level. For a typical 40 cm scan length of DIBH, the residual baseline drift was significantly (p-value<0.001) mitigated from 2.84 ± 0.22 mm to 0.64 ± 0.06 mm.

conclusionThe proposed calibration method provides a robust solution to minimize block positioning uncertainty and reduce baseline drift caused by CT couch sagging, enhancing the repeatability and accuracy of the wall-mounted camera calibration. Its versatility for wall- and ceiling-mounted cameras further expands its potential clinical utility.

Indexed as

Tomography, X-Ray ComputedCalibrationHumansPhantoms, ImagingRespiration

Identifiers

PMID41021589
PMCPMC12478875

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.